Scandinavian journal of thoracic and cardiovascular surgery
-
Scand J Thorac Cardiovasc Surg · Jan 1995
ReviewRepeated repair of tetralogy of Fallot. Report of 11 cases and review of the literature.
Eleven patients underwent late repeated correction of tetralogy of Fallot in 1991-1993. The previous operation was repair of simple Fallot's tetralogy in seven cases, repair plus transannular patch in one case and repair of tetralogy and pulmonic atresia in three cases. The indications for reoperation were residual ventricular septal defect, right ventricular outflow tract (R. ⋯ There were no death during 2 years of follow-up. Repeated correction of tetralogy of Fallot thus had low postoperative morbidity and good haemodynamic results. For the relatively few patients initially found to have tetralogy of Fallot and pulmonic atresia, the outcome may be less favorable.
-
Scand J Thorac Cardiovasc Surg · Jan 1995
Randomized Controlled Trial Clinical TrialCirculating cytokines and granulocyte-derived enzymes during complex heart surgery. A clinical study with special reference to heparin-coating of cardiopulmonary bypass circuits.
Blood contact with artificial surfaces during cardiopulmonary bypass (CPB) triggers a systemic inflammatory response in which complement, granulocytes and cytokines play a major role. Heparin-coated CPB circuits were recently shown to reduce complement and granulocyte activation in such circumstances. The present study comprised 20 complex heart operations, 10 with heparin-coated circuits (group HC) and 10 controls (group C), with evaluation of changes in terminal complement complex, the granulocyte enzymes myeloperoxidase and lactoferrin, and the cytokines interleukin-6 (IL-6) and interleukin-8 (IL-8). ⋯ IL-6 and IL-8 also increased significantly, but tended to be lower in the HC group, starting at CPB end and continuing until 20 hours postoperatively: for IL-6 the difference was significant at CPB end (83 +/- 18 vs 197 +/- 39 micrograms/l, p = 0.21). Significantly increased inflammatory response was thus found during complex heart operations even with use of heparin-coated CPB sets. The heparin-coating of circuits seems to diminish cytokine production.
-
Scand J Thorac Cardiovasc Surg · Jan 1995
Randomized Controlled Trial Clinical TrialThrombin generation during cardiopulmonary bypass using heparin-coated or standard circuits.
For quantitative comparison of thrombin generation during cardiopulmonary bypass (CPB) with heparin-coated vs conventional CPB circuits, thrombin-antithrombin III complex (TAT) and prothrombin fragment 1 + 2 (F1 + 2) were analyzed in 20 patients undergoing combined heart valve surgery and coronary artery bypass grafting (CABG), in ten cases with heparin-coated circuits (COMB-HC) and in ten with standard circuits (COMB-C). Extensive thrombin generation was found in both groups, with maximal TAT and F1 + 2 levels at the end of CPB. Of 15 operations with only CABG, seven were performed with heparin-coated circuits and heparin dose 40% of normal (CABG-HC), and eight with standard circuits and normal heparin doses (CABG-C). ⋯ The abundant thrombin generation during CPB thus was much more pronounced during complex operations. Use of heparin-coated circuits did not reduce thrombin generation, which was increased by 60% reduction of the systemic heparin dose. The clinical implications are still unknown, as no complications were observed.