The spine journal : official journal of the North American Spine Society
-
Randomized Controlled Trial Comparative Study
The comparison of pedicle screw and cortical screw in posterior lumbar interbody fusion: a prospective randomized noninferiority trial.
Pedicle screws (PS) offer great benefits in posterior lumbar interbody fusion (PLIF), but several drawbacks of PS, including the risk of superior facet joint violation and muscle injury, have also pointed out. Recently, cortical screws (CS) were invented, which can be placed without the drawbacks associated with PS. However, whether CS in PLIF can provide similar or greater clinical and radiologic outcomes compared to those of PS has not been fully evaluated in clinical research studies. ⋯ CS in PLIF provides similar clinical and radiologic outcomes compared to PS in PLIF. On the basis of the present study, we suggest CS to be a reasonable alternative to PS in PLIF.
-
Randomized Controlled Trial
Postdural puncture headache: impact of needle type, a randomized trial.
The most common adverse event after a lumbar puncture (LP) is a headache: In anaesthesiology, well studied is the protective effect of atraumatic spinal needles, and they are routinely used. However, this is less well known in diagnostic LP, and neurologists use atraumatic needles in less than 2% of times. ⋯ We found a lower incidence of PDPH with atraumatic needles, and it was statistically significant compared with the traumatic needles. Our study confirms the effectiveness of the atraumatic needles to prevent PDPH.