• Spine · Oct 2014

    Biomechanical evaluation of the suture anchors used in open-door laminoplasty: a cadaveric study.

    • Yoshitaka Kurokawa, Yasuharu Yokoyama, Koichi Kuroda, Sarath Koruprolu, David Paller, Atsushi Nakano, Ichiro Baba, and Masashi Neo.
    • *Department of Orthopedic Surgery, Osaka Medical College, Osaka, Japan †Olympus Terumo Biomaterials Corp., Tokyo, Japan; and ‡Department of Orthopedics, Warren Alpert Medical School of Brown University and Rhode Island Hospital, Providence, RI.
    • Spine. 2014 Oct 1;39(21):E1248-55.

    Study DesignA cadaveric study.ObjectiveTo determine whether the use of suture anchors is warranted in cervical laminoplasty.Summary Of Background DataThe use of suture anchors to stabilize elevated laminae has been popularized in laminoplasty. However, the validity of using suture anchors in laminoplasty has not been determined.MethodsSix intact fresh frozen cadavers were used. Open-door laminoplasty with a hinge on the cadaver's left side was performed on levels C3-C7. Elevated laminae were stabilized by suture anchors equipped with strain gauges, which were placed on C3, C5, and C7 left lateral masses. After surgery, the cervical spine was manually loaded passively, and the mechanical loads on each suture anchor during each motion were measured. Finally, the incision was opened again, and the failure loads of the suture anchors were also measured.ResultsAfter cervical loading, all elevated laminae were confirmed to be intact without dislodgement or failure of the suture anchors. The loads during left rotation and left bending were significantly higher than those during the respective motion to the right at all levels, except in rotation at C3. The loads on the C5 anchors in flexion and left rotation and on the C7 anchors in extension were relatively high. The maximum load obtained in the present study was 14.9 N, which was one order of magnitude lower than the mean failure load of the suture anchors (131.7 N).ConclusionBiomechanical laterality was demonstrated, reflecting the asymmetrical nature of open-door laminoplasty. The maximum load on the suture anchors was much lower than the failure load and was consistent with the stability of the suture anchors encountered in clinical cases. This may support the validity of using suture anchors in laminoplasty, although the loads during active motion may be higher than our results.Level Of EvidenceN/A.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.