• Journal of anesthesia · Apr 2021

    The ability of pulse oximetry-derived peripheral perfusion index to detect fluid responsiveness in patients with septic shock.

    • Ahmed Hasanin, Nadia Karam, Ahmed M Mukhtar, and Sara F Habib.
    • Department of Anesthesia and Critical Care Medicine, Cairo University, Cairo, Egypt. ahmed.hasanin@kasralainy.edu.eg.
    • J Anesth. 2021 Apr 1; 35 (2): 254-261.

    BackgroundFluid challenge test is a widely used method for the detection of fluid responsiveness in acute circulatory failure. However, detection of the patient's response to the fluid challenge requires monitoring of cardiac output which is not feasible in many settings. We investigated whether the changes in the pulse oximetry-derived peripheral perfusion index (PPI), as a non-invasive surrogate of cardiac output, can detect fluid responsiveness using the fluid challenge test or not.MethodsWe prospectively enrolled 58 patients with septic shock on norepinephrine infusion. Fluid challenge test, using 200 mL crystalloid solution, was performed in all study subjects. All patients received an additional 300 mL crystalloid infusion to confirm fluid responsiveness. Velocity time integral (VTI) (using transthoracic echocardiography), and PPI were measured at the baseline, after 200 mL fluid challenge, and after completion of 500 mL crystalloids. Fluid responsiveness was defined by 10% increase in the VTI after completion of the 500 mL. The predictive ability of ∆PPI [Calculated as (PPI after 200 mL - baseline PPI)/baseline PPI] to detect fluid responders was obtained using the receiver operating characteristic curve.ResultsForty-two patients (74%) were fluid responders; in whom, the mean arterial pressure, the central venous pressure, the VTI, and the PPI increased after fluid administration compared to the baseline values. ∆PPI showed moderate ability to detect fluid responders [area under receiver operating characteristic curve (95% confidence interval) 0.82 (0.70-0.91), sensitivity 76%, specificity 80%, positive predictive value 92%, negative predictive value 54%, cutoff value ≥ 5%]. There was a significant correlation between ∆PPI and ∆VTI induced by the fluid challenge.Conclusion∆PPI showed moderate ability to detect fluid responsiveness in patients with septic shock on norepinephrine infusion. Increased PPI after 200 mL crystalloid challenge can detect fluid responsiveness with a positive predictive value of 92%; however, failure of the PPI to increase does not exclude fluid responsiveness.Clinical Trial IdentifierNCT03805321. Date of registration: 15 January 2019. Clinical trial registration URL: https://clinicaltrials.gov/ct2/show/NCT03805321?term=ahmed+hasanin&rank=9 .

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.