• Anesthesiology · May 2021

    Reverse Triggering Dyssynchrony 24 h after Initiation of Mechanical Ventilation.

    • Ricard Mellado Artigas, L Felipe Damiani, Thomas Piraino, Tai Pham, Lu Chen, Michela Rauseo, Irene Telias, Ibrahim Soliman, Detajin Junhasavasdikul, César Santis, Orla M Smith, Ewan Goligher, Norman Comtois, Christer Sinderby, Leo Heunks, and Laurent Brochard.
    • Anesthesiology. 2021 May 1; 134 (5): 760-769.

    BackgroundReverse triggering is a delayed asynchronous contraction of the diaphragm triggered by passive insufflation by the ventilator in sedated mechanically ventilated patients. The incidence of reverse triggering is unknown. This study aimed at determining the incidence of reverse triggering in critically ill patients under controlled ventilation.MethodsIn this ancillary study, patients were continuously monitored with a catheter measuring the electrical activity of the diaphragm. A method for automatic detection of reverse triggering using electrical activity of the diaphragm was developed in a derivation sample and validated in a subsequent sample. The authors assessed the predictive value of the software. In 39 recently intubated patients under assist-control ventilation, a 1-h recording obtained 24 h after intubation was used to determine the primary outcome of the study. The authors also compared patients' demographics, sedation depth, ventilation settings, and time to transition to assisted ventilation or extubation according to the median rate of reverse triggering.ResultsThe positive and negative predictive value of the software for detecting reverse triggering were 0.74 (95% CI, 0.67 to 0.81) and 0.97 (95% CI, 0.96 to 0.98). Using a threshold of 1 μV of electrical activity to define diaphragm activation, median reverse triggering rate was 8% (range, 0.1 to 75), with 44% (17 of 39) of patients having greater than or equal to 10% of breaths with reverse triggering. Using a threshold of 3 μV, 26% (10 of 39) of patients had greater than or equal to 10% reverse triggering. Patients with more reverse triggering were more likely to progress to an assisted mode or extubation within the following 24 h (12 of 39 [68%]) vs. 7 of 20 [35%]; P = 0.039).ConclusionsReverse triggering detection based on electrical activity of the diaphragm suggests that this asynchrony is highly prevalent at 24 h after intubation under assist-control ventilation. Reverse triggering seems to occur during the transition phase between deep sedation and the onset of patient triggering.Editor’s PerspectiveCopyright © 2021, the American Society of Anesthesiologists, Inc. All Rights Reserved.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…