• Arch Orthop Trauma Surg · Apr 2015

    Comparison of treatment of oblique and spiral metacarpal and phalangeal fractures with mini plate plus screw or screw only.

    • Hakan Başar, Betül Başar, Onur Başçı, Osman Mert Topkar, Bülent Erol, and Cihangir Tetik.
    • Department of Orthopaedics and Traumatology, Sakarya Training and Research Hospital, Eski Kazımpaşa cad. yolu Arabacı alanı mah.Akkent villaları NO:156/25, Serdivan, Sakarya, Turkey, hbasar80@hotmail.com.
    • Arch Orthop Trauma Surg. 2015 Apr 1;135(4):499-504.

    IntroductionWe aimed to compare results of treatment of oblique-spiral metacarpal and phalangeal fractures with screw only or mini plate plus screw, respectively.MethodsA total of 43 patients who were operated with a diagnosis of displaced, irreducible, unstable, rotational oblique-spiral metacarpal and proximal phalangeal fracture between 2007 and 2010 were included in this study. The mean age of patients with a phalangeal fracture was 33.8 years (range 20-50 years; 4 females, 18 males), and the mean age of patients with a metacarpal fracture was 29.6 years (range 18-45 years; 3 females, 18 males). Mini plate plus screw or screw only was used for internal fixation of these fractures. The patients were followed up for 19.2 ± 5.4 months in the phalangeal fracture group and 20.9 ± 7.3 months in metacarpal fracture group. Of the metacarpal fractures, 14 were oblique and 10 spiral, whereas 14 of the phalangeal fractures were oblique and 8 spiral. The patients were evaluated according to total range of motion of the finger, grasping strength and Q-DASH score.ResultsFor patients treated with mini plate plus screw after metacarpal and phalangeal fractures, the time to return to work was significantly shorter in comparison to patients treated with screws only. There was no significant difference between patients with metacarpal fractures treated with mini plate plus screw and patients treated with screw only in terms of total range of motion and Q-DASH results at last on control examination, while results of patients with phalangeal fractures treated with screw only were significantly better. There was no significant difference between these two treatments in phalangeal fractures in terms of grasping strength of the finger in early (1st month) and late (last control examination), whereas patients with metacarpal fractures treated with mini plate plus screw reached higher grasping strength earlier.ConclusionTreatment with mini plate plus screw should be avoided in spiral and oblique phalangeal fractures, and fixation should be done with screw only with a short surgical incision and dissection. On the other hand, treatment with mini plate plus screw should be preferred in patients with spiral and oblique metacarpal fractures, especially in those who work in occupations requiring higher physical strength.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.