• Spine · Apr 2021

    In-vitro 3D Analysis of Sacroiliac Joint Kinematics: Primary and Coupled Motions.

    • Khalid Odeh, Wei Wu, Ben Taylor, Jeremi Leasure, and Dimitriy Kondrashov.
    • St. Mary's Medical Center, San Francisco Orthopaedic Residency Program, San Francisco, CA.
    • Spine. 2021 Apr 15; 46 (8): E467-E473.

    Study DesignAn in-vitro biomechanical study of human cadaver sacroiliac joints.ObjectiveOur study aimed to develop a more comprehensive understanding of the native motion of the SIJ within the context of spinal kinematics and spinal implant evaluation.Summary Of Background DataIncreasing attention has been given to the sacroiliac joint (SIJ) as a source of low back pain, despite its limited range of motion. We sought to characterize the rotational and translational motion in each axis utilizing standard pure moment flexion-extension (FE), lateral bending (LB), and axial rotation (AR) testing.MethodsSixteen sacroiliac joints were evaluated from eight lumbosacral cadaver specimens (six females, two males) from subjects aged 28 to 57 years (mean age 46.8) with body mass index (BMI) 22 to 36 (mean BMI 30). Single leg stance was modeled by clamping the blocks on one ischium in a vise and letting the contralateral ischium hang freely. Pure moment loading was applied in FE, right/left AR, and right/left LB. Relative motions were collected with infrared markers.ResultsThe on-axis ratio was significantly lower in LB than in FE (P = 0.012) and in AR (P = 0.017). The rotation deviation angle measured 13.9 ± 9.1° in FE, 17.1 ± 8.7° in AR, and 35.7 ± 25.7° in LB. In LB the rotational deviation angle is significantly higher than both FE and AR (P = 0.003 and P = 0.011, respectively). In-plane translation was significantly higher (P = 0.005) in FE loading than in LB loading.ConclusionA nontrivial amount of rotation and translation occurred out of the expected axis of motion. The largest amount of off-axis rotation was observed in lateral bending. Relative to resultant translation, in-plane translation was lowest in lateral bending. Our results indicate that rotation of the SIJ is not fully described with the in-plane metrics which are normally reported in evaluation of fusion devices. Future studies of the SIJ may need to consider including off-axis rotation measurements when describing SIJ kinematics.Level of Evidence: 5.Copyright © 2021 Wolters Kluwer Health, Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.