- Donita I Bylski-Austrow, David L Glos, Frank E Sauser, Viral V Jain, Eric J Wall, and Alvin H Crawford.
- Department of Orthopaedics, Cincinnati Children's Hospital Medical Center, Cincinnati, OH 45229, USA. donita.bylski-austrow@cchmc.org
- Spine. 2012 Jul 15;37(16):E949-56.
Study DesignIn vivo biomechanical study in quadruped model.ObjectiveTo develop in vivo model capable of determining physiological compressive stresses bilaterally in the intervertebral disc annulus and preliminarily assess effects of a hemiepiphyseal implant.Summary Of Background DataSpine growth modification alters stress distributions in vertebral growth plates and discs. Quantification of stresses is required to help assess implant efficacy and disc health. More generally, despite widespread and necessary use of animals in preclinical studies of spine instrumentation, limited quantitative information is available on mechanobiological conditions in quadruped spines for comparisons with those of humans.MethodsSkeletally immature domestic pigs were instrumented with an implant and 4 stress sensors. Sensors were inserted into left and right sides of the annulus at 2 thoracic levels. A titanium staple-screw construct was implanted at 1 level. Signals were acquired intraoperatively, postoperatively during normal activities, and biweekly with the animal under anesthesia, for up to 8 weeks.ResultsStresses varied by sensor location relative to implant, postoperative time, activity, and animal. Intraoperatively, the mean peak stress due to staple insertion was 1.6 MPa at the sensor nearest the staple. Mean stress at the end of surgery was 0.23 MPa. Mean stress standing the first day was 0.38 MPa. Dynamic stresses were recorded at all locations, including the location nearest the staple. Highest mean stresses were those nearest the implant. With the animal under anesthesia, the dynamic stress range in the resting prone position was 0.1 MPa, whereas this range was 0.9 MPa when the spine was manually flexed.ConclusionCompressive stresses were dynamic at both control and stapled levels, which indicated that the disc was not immobilized by the implant. These pilot results suggested that mean disc compression was increased within the first postoperative week. Stresses ranged up to levels measured in humans.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.