• World Neurosurg · Sep 2015

    Case Reports

    A Single-Center Experience with the NeuroPace RNS System: A Review of Techniques and Potential Problems.

    • Brian Lee, Muhammad N Zubair, Yvette D Marquez, David M Lee, Laura A Kalayjian, Christianne N Heck, and Charles Y Liu.
    • Department of Neurosurgery, University of Southern California, Keck School of Medicine, Los Angeles, California, USA. Electronic address: brianlee@usc.edu.
    • World Neurosurg. 2015 Sep 1;84(3):719-26.

    IntroductionThe clinical results for the RNS System (NeuroPace, Mountain View, California, USA) closed-loop responsive neurostimulator for the treatment of medically intractable partial-onset seizures have been encouraging. The University of Southern California (USC) Neurorestoration Center and the Keck Hospital of USC have become the world's first institutions to implant an RNS System post U.S. Food and Drug Administration (FDA) approval. As one of the study centers, we review our experience with our group of patients who have been implanted with the RNS System.MethodsA total of 40 surgeries by a single surgeon were performed on 10 patients (7 male and 3 female) with an average age of 39.2 years (24-66 years) and were followed for an average of 45 months (30-54 months). The average age at seizure onset was 14 years (birth-37 years) with an average of 4.7 (3-12) failed antiepileptic drugs. We reviewed the patients' charts for complications from the surgeries including infections requiring surgical intervention, hematomas, hardware failures, and death.ResultsOf the 40 surgeries, there were 10 initial implantations of the neurostimulator and leads, 24 neurostimulator replacements for expected end of neurostimulator service, 2 incision and drainage procedures (I & Ds) for soft tissue infection followed by 1 explantation and 1 reimplantation (same patient), and 2 revisions because of one lead that was damaged at the exit point between the skull and a titanium mesh and the second lead that was damaged at an acute bend over the skull (same patient). Eight of the patients had no complications and underwent an average of 2.7 neurostimulator replacements over 7 consecutive years to date. Each patient underwent routine postoperative computed tomography imaging of the brain, and none had any intracranial hematomas or misplaced leads requiring revision surgery. Finally, there were no deaths in our patient population.ConclusionsOur experience with the NeuroPace RNS System over an average follow-up of 45 months suggests that the surgery and device are safe when placed by an experienced surgeon. Although there were no clinically significant hematomas or patient deaths, we did have 1 patient each with infection and lead damage at the point of exit from the skull. We compare the results of this study with other neuromodulation procedures for epilepsy to evaluate the safety and complications associated with the RNS System. Our initial experience suggests that the RNS System can be readily incorporated into an active epilepsy surgical center.Copyright © 2015 Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…