• Annu Int Conf IEEE Eng Med Biol Soc · Aug 2015

    Evaluation of the variation in sensory test results using Semmes-Weinstein monofilaments.

    • Manabu Chikai, Emi Ozawa, Noriyo Takahashi, Kiyohiko Nunokawa, and Shuichi Ino.
    • Annu Int Conf IEEE Eng Med Biol Soc. 2015 Aug 1; 2015: 1259-62.

    AbstractThe purpose of this study is to examine the variability in sensory test of tactile results using Semmes-Weinstein monofilament (SWM). At present, several methods for measuring the tactile sensitivity are clinically used in diabetic peripheral neuropathy screening. One of these methods is a touch test that uses a device with nylon SWMs, i.e., SWMs embedded in a plastic handle. A small pushing force is applied at the handle to bow the filaments. Because of its ease and simplicity, the SWM test is conducted at the patient's bedside in a hospital. However, previous studies have reported some problems with this test. Studies have shown variations in the measured data, and it is uncertain whether these variations are caused by mechanical properties of the nylon fiber or by the motion of the operator's hands. We carried out two experiments to examine the effect of (1) the variability caused by the human operator conducting the SWM test on the test results and (2) the number of compressions of the SWM on the test results. In experiment 1, we measured the velocity of the operator's hand motion and the buckling force of the SWMs. The results showed variability in the hand motion of the operator conducting the SWM tests. In experiment 2, we measured the buckling force of the SWMs under a controlled velocity. We compared the buckling force of the SWMs through a number of trials. These results showed that the buckling force gradually decreases as the number of test cycles increase. In conclusion, we find that the accuracy of the SWM tests is a factor of the number of test cycles. Additionally, manual training for standardizing skills of medical staff members needs to be developed. Furthermore, the characteristics of the SWMs deteriorated over time. In future work, we aimto find a solution to minimize the variability in the SWM test results and develop a new testing system that uses tactile sensibility for diabetic peripheral neuropathy screening.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?

    User can't be blank.

    Content can't be blank.

    Content is too short (minimum is 15 characters).

    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.