Randomized Controlled Trial
Five-year Follow-up of a Prospective, Randomized Trial Comparing Two Lumbar Total Disc Replacements.
- Richard D Guyer, Kenneth Pettine, Jeffrey S Roh, Thomas A Dimmig, Domagoj Coric, Paul C McAfee, and Donna D Ohnmeiss.
- *Texas Back Institute, Plano, TX †Loveland Orthopedic Clinic, Loveland, CO ‡Proliance Surgeons, Seattle, WA §Triangle Orthopaedic Associates, Durham, NC ¶Carolina Neurosurgery and Spine Associates, Charlotte, NC ||Towson Orthopaedic Associates, Scoliosis and Spine Center, Towson, MD #Texas Back Institute Research Foundation, Plano, TX.
- Spine. 2016 Jan 1; 41 (1): 3-8.
Study DesignThis was a prospective, randomized, controlled, multicenter study.ObjectiveThe purpose of this study was to compare outcomes of two lumbar total disc replacements (TDRs) at 5-year follow-up and report results of serum ion level analysis in a subgroup of patients receiving a metal-on-metal implant.Summary Of Background DataLumbar TDR has been compared with fusion in several randomized studies, finding TDR noninferior to fusion and superior on some measures. Receiving less attention has been comparing TDR devices. Additionally, there is concern about metal-on-metal implants, with little data available for spine devices.MethodsThe study included 204 patients receiving Kineflex-L (investigational) and 190 receiving CHARITÉ (control). Outcome measure included Oswestry Disability Index, visual analog pain scales (VAS), patient satisfaction, neurological status, complications, reoperations, and a composite success score. Radiographic assessment included range of motion, subsidence, and heterotrophic ossification. In 32 investigational patients, serum ion analysis was performed for cobalt and chromium. These values were compared with Medicines and Healthcare Products Regulatory Agency values to merit monitoring total hip replacement patients for potential wear problems.ResultsMean Oswestry and VAS scores in both groups improved significantly by 6 weeks and remained improved during 5-year follow-up (Oswestry Disability Index, scores in both groups were approximately 60 preoperatively vs. 20 at 2- and 5-year follow-up; P < 0.01; VAS scores improved >50% by 6 weeks and remained significantly improved; P < 0.05). Approximately 11% of both groups underwent reoperation. Radiographic analysis found segmental range of motion decreased at 3 month, then increased through 24 months, and was maintained thereafter. Serum ion level analysis found the greatest mean value at any follow-up point was less than 20% of Medicines and Healthcare Products Regulatory Agency recommended minimum value to merit monitoring hip replacement patients.ConclusionThis prospective, randomized study comparing two TDRs found no significant differences in outcomes during 5-year follow-up. Both provided statistically significant improvements by 6 weeks that were maintained. This results support other studies. Serum ion levels in TDR patients were well below the recommended threshold levels to merit monitoring.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.