• Reg Anesth Pain Med · Oct 2021

    Observational Study

    Opening injection pressure monitoring using an in-line device does not prevent intraneural injection in an isolated nerve model.

    • Jorge Mejia, Victor Varela, Javier Domenech, Pierre Goffin, Alberto Prats-Galino, and Xavier Sala-Blanch.
    • Anesthesiology, Hospital Clinic de Barcelona, Barcelona, Spain.
    • Reg Anesth Pain Med. 2021 Oct 1; 46 (10): 916-918.

    BackgroundInjection pressure monitoring using in-line devices is affordable and easy to implement into a regional anesthesia practice. However, solid evidence regarding their performance is lacking. We aimed to evaluate if opening injection pressure (OIP), measured with a disposable in-line pressure monitor, can prevent intraneural (subepineural) injection using 15 pound per square inch (PSI) as the reference safety threshold.MethodsAn isolated nerve model with six tibial and six common peroneal nerves from three unembalmed fresh cadavers was used for this observational study. A mixture of 0.5% ropivacaine with methylene blue was injected intraneurally at a rate of 10 mL/min, to a maximum of 3 mL. OIP was recorded for each injection as well as evidence of intraneural contrast. Injected volume at 15 and 20 PSI was recorded, and when it leaked out the epineurium, if it occurred.ResultsIn all cases, OIP was<15 PSI and intraneural contrast was evident before the safety threshold. The 15-20 PSI mark was attained in 5 of 12 injections (41%), with a median injected volume of 0.9 mL (range 0.4-2.3 mL). Peak pressure of >20 PSI was reached in two injections (at 0.6 mL and 2.7 mL). Contrast leaked out the epineurium in 11 of 12 injections (91%) with a median injected volume of 0.6 mL (range 0.1-1.3 mL).ConclusionsOur results suggest that in-line pressure monitoring may not prevent intraneural injection using an injection pressure of 15 PSI as reference threshold. Due to the preliminary nature of our study, further evidence is needed to demonstrate clinical relevance.© American Society of Regional Anesthesia & Pain Medicine 2021. No commercial re-use. See rights and permissions. Published by BMJ.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…