• Arch Orthop Trauma Surg · Dec 2021

    Handheld computer-navigated constrained total knee arthroplasty for complex extra-articular deformities.

    • M Pietsch, M Hochegger, O Djahani, G Mlaker, M Eder-Halbedl, and Th Hofstädter.
    • Department of Orthopaedic Surgery, Orthopaedic Hospital Stolzalpe (LKH Murtal), Stolzalpe 38, 8852, Stolzalpe, Austria. martin.pietsch@lkh-stolzalpe.at.
    • Arch Orthop Trauma Surg. 2021 Dec 1; 141 (12): 2245-2254.

    IntroductionThe present study aimed to assess the postoperative alignment and clinical outcomes of patients with complex extra-articular deformities (EADs) undergoing computer-assisted surgery (CAS) for constrained total knee arthroplasty (TKA) with modular stem extensions.Materials And MethodsFrom May 2015 to July 2018, ten patients with EADs scheduled for constrained TKA were enrolled retrospectively. The preoperative average deviation from neutral (= 180°) mechanical axis was 15.3° (range of coronal alignment: 150.9° varus-202.9° valgus). Alignment was assessed using an accelerometer-based handheld CAS system. On long-leg films, the positions of the components and possible stems were analysed and templated preoperatively. The average follow-up was 3.3 years (range: 2.0-4.6 years).ResultsThe postoperative mechanical axis was within ± 3.0° from neutral in nine patients. In all patients, the Knee Society score (KSS) and range of motion improved significantly. A constrained condylar and a rotating hinge prosthesis were used in five patients each. In eight patients, the 100-mm cementless stem that was preferred by the authors was found to be unusable for the femur or the tibia in the planning stage. For the femur, a cementless 100-mm stem was used in three, and a cemented 30-mm stem in five patients; a femoral stem was not usable in two patients. For the tibia, a cementless 100-mm stem was used in six, and a cemented 30-mm stem in two patients; a monoblock rotating hinge tibia was used in two patients.ConclusionsComplex EADs were excellently managed during constrained TKA implantation using the handheld CAS system. Templating allowed the possible stem lengths to be identified and prevented anatomical conflict with the CAS-configured mechanical alignment. Limb alignment and function improved significantly after surgery. No intra- or postoperative complications occurred.Level Of EvidenceLevel IV, retrospective study.© 2021. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…