• Anesthesiology · Sep 2008

    Transmission of pathogenic bacterial organisms in the anesthesia work area.

    • Randy W Loftus, Matthew D Koff, Corey C Burchman, Joseph D Schwartzman, Valerie Thorum, Megan E Read, Tammara A Wood, and Michael L Beach.
    • Department of Anesthesiology, Dartmouth-Hitchcock Medical Center, 1 Medical Center Drive, Lebanon, New Hampshire 03756, USA. randy.loftus@hitchcock.org
    • Anesthesiology. 2008 Sep 1;109(3):399-407.

    BackgroundThe current prevalence of hospital-acquired infections and evolving amplification of bacterial resistance are major public health concerns. A heightened awareness of intraoperative transmission of potentially pathogenic bacterial organisms may lead to implementation of effective preventative measures.MethodsSixty-one operative suites were randomly selected for analysis. Sterile intravenous stopcock sets and two sites on the anesthesia machine were decontaminated and cultured aseptically at baseline and at case completion. The primary outcome was the presence of a positive culture on the previously sterile patient stopcock set. Secondary outcomes were the number of colonies per surface area sampled on the anesthesia machine, species identification, and antibiotic susceptibility of isolated organisms.ResultsBacterial contamination of the anesthesia work area increased significantly at the case conclusion, with a mean difference of 115 colonies per surface area sampled (95% confidence interval [CI], 62-169; P < 0.001). Transmission of bacterial organisms, including vancomycin-resistant enterococcus, to intravenous stopcock sets occurred in 32% (95% CI, 20.6-44.9%) of cases. Highly contaminated work areas increased the odds of stopcock contamination by 4.7 (95% CI, 1.42-15.42; P = 0.011). Contaminated intravenous tubing was associated with a trend toward increased nosocomial infection rates (odds ratio, 3.08; 95% CI, 0.56-17.5; P = 0.11) and with an increase in mortality (95% CI odds ratio, 1.11-infinity; P = 0.0395).ConclusionPotentially pathogenic, multidrug-resistant bacterial organisms are transmitted during the practice of general anesthesia to both the anesthesia work area and intravenous stopcock sets. Implementation of infection control measures in this area may help to reduce both the evolving problem of increasing bacterial resistance and the development of life-threatening infectious complications.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…