• Resp Care · Oct 2006

    Randomized Controlled Trial

    The effects of apparatus dead space on P(aCO2) in patients receiving lung-protective ventilation.

    • Carl R Hinkson, Michael S Benson, Lauri M Stephens, and Steven Deem.
    • Department of Respiratory Care, Harborview Medical Center, Mail Stop 359761, 325 9th Avenue, Seattle, WA 98104, USA. gooddog@u.washington.edu
    • Resp Care. 2006 Oct 1;51(10):1140-4.

    BackgroundLung-protective ventilation using tidal volume (V(T)) of 4-6 mL/kg (predicted body weight) reduces mortality (compared with traditional V(T)) in patients with acute respiratory distress syndrome and acute lung injury. Standardized use of lower V(T) can result in respiratory acidosis and has raised new concerns about the appropriate configuration of the ventilator circuit, especially in regard to the dead space (V(D)) of the apparatus. We hypothesized that, with a patient receiving lung-protective ventilation, the removal of all apparatus dead space from the circuit would reduce P(aCO2) and allow a reduction in minute ventilation.MethodsAll the studied patients met the American-European consensus-conference criteria for acute respiratory distress syndrome/acute lung injury, were receiving a lung-protective ventilation strategy, were > 18 years of age, and were hemodynamically stable. We prospectively tested 3 different ventilator-circuit configurations, in random sequence, for 15 min each: (1) standard hygroscopic heat-and-moisture exchanger (HME) with 15-cm flexible tubing, (2) 15-cm flexible tubing only, (3) no HME or flexible tubing. V(T), respiratory rate, positive end-expiratory pressure, and fraction of inspired oxygen were maintained constant throughout the study, and exhaled CO2 was measured continuously. Physiologic dead space (V(D)/V(T)) was calculated using the Enghoff modification of the Bohr equation.ResultsSeven patients were studied. Removal of the HME from the circuit significantly decreased V(D)/V(T) (by approximately 6%) and P(aCO2) (by approximately 5 mm Hg). Removal of both the HME and flexible tubing from the circuit reduced V(D)/V(T) by an additional 5%, and P(aCO2) by an additional 6 mm Hg. With both circuit-configuration changes, minute ventilation fell from a mean of 11.51 L/min to 10.35 L/min, and pH increased from 7.30 to 7.38. Carbon-dioxide production did not change significantly.ConclusionIn patients receiving lower-V(T) ventilation, removing all the apparatus V(D) from the ventilator circuit reduces P(aCO2) and increases pH, at a lower minute ventilation. This information will help guide ventilator-circuit configuration for patients receiving lung-protective ventilation.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.