• Acta Anaesthesiol Scand · Feb 2024

    Observational Study

    Flexible bronchoscopic intubation through a supraglottic airway device: An evaluation of consultant anaesthetist performance.

    • Christine N Svendsen, Gine L Glargaard, Lars H Lundstrøm, Charlotte V Rosenstock, Anne C Haug, Arash Afshari, Rasmus Hesselfeldt, and Camilla Strøm.
    • Department of Anaesthesiology, New North Zealand Hospital, Hillerød, Denmark.
    • Acta Anaesthesiol Scand. 2024 Feb 1; 68 (2): 178187178-187.

    BackgroundFew clinical studies investigate technical skill performance in experienced clinicians.MethodsWe undertook a prospective observational study evaluating procedural skill competence in consultant anaesthetists who performed flexible bronchoscopic intubation (FBI) under continuous ventilation through a second-generation supraglottic airway device (SAD). Airway management was recorded on video and performance evaluated independently by three external assessors. We included 100 adult patients undergoing airway management by 25 anaesthetist specialists, each performing four intubations. We used an Objective Structured Assessment of Technical Skills-inspired global rating scale as primary outcome. Further, we assessed the overall pass rate (proportion of cases where the average of assessors' evaluation for every domain scored ≥3); the progression in the global rating scale score; time to intubation; self-reported procedural confidence; and pass rate from the first to the fourth airway procedure.ResultsOverall median global rating scale score was 29.7 (interquartile range 26.0-32.7 [range 16.7-37.7]. At least one global rating scale domain was deemed 'not competent' (one or more domains in the evaluation was scored <3) in 30% of cases of airway management, thus the pass rate was 70% (95% CI 60%-78%). After adjusting for multiple testing, we found a statistically significant difference between the first and fourth case of airway management regarding time to intubation (p = .006), but no difference in global rating scale score (p = .018); self-reported confidence before the procedure (p = .014); or pass rate (p = .109).ConclusionConsultant anaesthetists had a median global rating scale score of 29.7 when using a SAD as conduit for FBI. However, despite reporting high procedural confidence, at least one global rating scale domain was deemed 'not competent' in 30% of cases, which indicates a clear potential for improvement of skill competence among professionals.© 2023 Acta Anaesthesiologica Scandinavica Foundation.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…