    [Validation of two systems of self-measurement of blood pressure, the OMRON HEM-705 CP and OMRON M1 (HEM 422C2-E) models].

    • P Iglesias Bonilla, E Mayoral Sánchez, J Lapetra Peralta, M Iborra Oquendo, F Villalba Alcalá, and A Cayuela Domínguez.
    • Unidad Docente de Medicina Familiar y Comunitaria de Sevilla. Hospital Universitario Virgen del Rocio. Sevilla. Spain. pib71@supercable.es
    • Aten Primaria. 2002 Jun 15; 30 (1): 222822-8.

    AbstractObjective. To validate two monitors on the market for self-measurement of blood pressure (SMBP), an automatic one (OMRON HEM-705 CP) and a semi-automatic one (OMRON M1).Design. Descriptive study of validation of diagnostic tests.Setting. Primary care. San Pablo University Health Centre, Sevilla.Participants. 85 individuals (20 men and 65 women) with a wide range of age and blood pressure (BP), belonging to the population attended at the health centre or to its staff. People with arrhythmia and Korotkoff's V phase close to zero were excluded. Main measurements and results. BP and cardiac frequency (CF) measurements obtained with the SMBP devices to be validated were compared with readings on a mercury sphygmomanometer, used as the standard method. The differences between the SMBP devices and the gold standard were quantified and are presented on the scale proposed by the protocol of the British Hypertension Society (BHS). The mean (SD) of the systolic BP differences (in mm Hg) between the devices evaluated and the standard device was 1.084.73 for the automatic monitor and 1.255.30 for the semi-automatic one. The mean differences of diastolic BP were 0.444.03 for the automatic monitor, and 0.513.90 for the semi-automatic one. The cumulative percentage differences of systolic/ diastolic BP5, 10 and 15 mm Hg were 85.5, 98, 98.8/90.6, 98.4, 100% for the automatic monitor and 82.7, 95.7, 98.8/91, 99.6, 100% for the semi-automatic one. This supposes a Grade A on the BHS procedure, which is maintained on analysis of the results by blood pressure rankings. Conclusion. As both monitors meet the internationally accepted validation criteria, they can be recommended for the monitoring and self-monitoring of BP in patients with hypertension.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.