-
Arch Orthop Trauma Surg · Dec 2024
Mid- to long-term clinical and radiological assessment of a short, titanium, porous plasma-splayed flat-tapered cementless femoral stem: An 8- to 12-year follow-up study.
- Kensuke Yoshino, Yoshitada Harada, Jin Miyagi, Yuya Ogawa, and Akito Nagai.
- Department of Orthopaedic Surgery, Chibaken Saiseikai Narashino Hospital, 1-1-1 Izumi-cho, Narashino city, 275-8580, Chiba, Japan. knskysn@gmail.com.
- Arch Orthop Trauma Surg. 2024 Dec 12; 145 (1): 1313.
IntroductionShort cementless stems offer advantages such as bone-stock preservation and minimally invasive insertion. Despite encouraging short- to midterm outcomes, the long-term clinical and radiological implications of short, titanium, and porous plasma-sprayed flat-tapered stems remain unclear.Materials And MethodsA retrospective review of 138 primary total hip arthroplasties, conducted between 2010 and 2015 in 130 patients, with a minimum 8-year follow-up was performed. Patients with Dorr type A or B femora were included. Clinical and radiographic results, complications, and survival rates were evaluated.ResultsA total of 102 hips (94 patients) were reviewed with complete clinical and radiographic data at a minimum 8-year follow-up (mean, 9.5 years). The modified Harris hip score significantly improved from a mean preoperative value of 40.1 to 97.8 at the final follow-up, with 91% of the hips achieving a score of ≥ 90. In the original cohort of 138 hips, none underwent revision surgery for symptomatic loosening. Perioperative complications occurred in eight hips, including femoral fractures, postoperative dislocation, subcutaneous abscess, and transient thigh pain. Radiographically, femoral stem alignment was predominantly neutral in 86% of the hips in the anteroposterior plane. No hip exhibited radiolucency > 1 mm, and no subsidence > 2 mm was observed. Bone ingrowth fixation was observed in all 102 hips. Stress shielding around or below the lesser trochanter occurred in 58% of hips. Kaplan-Meier survival analysis indicated a 100% survival rate at eight, 10, and 12 years for stem revision or radiological instability.ConclusionsThe short, titanium, porous, plasma-sprayed, flat-tapered cementless stem exhibited excellent mid- to long-term results in primary total hip arthroplasties with Dorr type A or B femora, comparable with those of other short cementless and standard-length stems. Noteworthy survivorship was observed; however, caution is advised regarding stress-shielding complications, particularly periprosthetic femoral fractures, during extended follow-up.© 2024. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.