Arch Orthop Trauma Surg · Jan 2025
Increased stiffness with medial column screw supplementation of lateral locking plate for distal femur fractures: a biomechanical study.
- Joseph Henningsen, Kyle Mobley, Scott Huff, Joshua Perrin, William Naylor, Andrew Froehle, Jennifer Jerele, and Michael Prayson.
- Department of Orthopaedics, Wright State University, 30 E Apple St., Suite 2200, Dayton, OH, 45409, USA. joedhenningsen@gmail.com.
- Arch Orthop Trauma Surg. 2025 Jan 24; 145 (1): 142142.
IntroductionWe propose and assess the biomechanical stability of medial column screw supplementation in a synthetic distal femur fracture model.Materials And MethodsTwenty-four low density synthetic femora modeling osteoporotic, intraarticular distal femur fractures with medial metaphyseal comminution were split into two fixation groups: (1) lateral locking distal femur plate (PA- plate alone) and (2) lateral locking distal femur plate with a 6.5 mm fully threaded medial cannulated screw (PWS- plate with screw). Cyclic biomechanical testing included 5 steps of 10,000 cycles with each step increasing axial loads starting at 0.5xBW (BW = 80 kg) up to 2.5xBW. Discrete stiffness was calculated for each step and cumulative stiffness was calculated across the entire protocol. Outcomes of interest included cumulative stiffness, discrete stiffness, and instrumentation failure.ResultsSeven of the PA models had failure during testing. No failures were seen in the PWS group. PWS had 19.8% higher cumulative stiffness compared to PA (676.3 N/mm vs 809.8 N/mm; P = 0.014). Discrete stiffness showed < 1% differences at lower loads, but increasing loads found the PWS group with 12% greater discrete stiffness than the PA group (879.1 N/mm vs 983.8 N/mm; P = 0.028).ConclusionThis is the first study to evaluate the contribution of a medial column screw in a distal femur fracture model. PWS had superior stiffness and few failures compared to PA. Applied clinically, a medial column screw can increase construct stability in the setting of complex distal femur fractures with minimal increase in operative time, patient morbidity and cost.© 2025. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.