• Anesthesiology · Jun 2006

    Randomized Controlled Trial Comparative Study

    Comparison of three disposable extraglottic airway devices in spontaneously breathing adults: the LMA-Unique, the Soft Seal laryngeal mask, and the Cobra perilaryngeal airway.

    • André van Zundert, Baha Al-Shaikh, Joseph Brimacombe, Jurgen Koster, Dick Koning, and Eric P Mortier.
    • Department of Anesthesiology, Intensive Care and Pain Therapy, Catharina Hospital-Brabant Medical School, Eindhoven, The Netherlands. zundert@iae.nl
    • Anesthesiology. 2006 Jun 1; 104 (6): 1165-9.

    BackgroundThe authors compared three disposable extraglottic airway devices in spontaneously breathing anesthetized adults: the LMA-Unique (LMA-U; The Laryngeal Mask Company, San Diego, CA), the Soft Seal laryngeal mask (SS-LM; Portex Ltd., Hythe, United Kingdom), and the Cobra perilaryngeal airway (Cobra-PLA; Engineered Medical Systems, Inc. Indianapolis, IN).MethodsThree hundred twenty consecutive adults (American Society of Anesthesiologists physical status I-III; aged 18-80 yr) were randomly allocated for airway management with one of the three devices. Anesthesia was with fentanyl-propofol for induction and a sevoflurane-nitrous oxide-oxygen-fentanyl mixture for maintenance. Intraoperative data were collected by an unblinded observer about ease of insertion, effective airway time, oropharyngeal leak pressure, anatomical position (determined with a rigid endoscope), intracuff pressure changes, and airway trauma. Data were collected by a blinded observer about sore throat, dysphagia, and dysphonia 2 h after surgery.ResultsInsertion was easier with the LMA-U and SS-LM than with the Cobra-PLA (P < 0.02), but the overall failure rates were similar. Effective airway times were similar among groups. Oropharyngeal leak pressure was lower with the LMA-U than with the SS-LM and Cobra-PLA (P < 0.001). Intracuff pressure increased during surgery with all extraglottic airway devices. Anatomical position was better with the Cobra-PLA than with the SS-LMA (P < 0.001) and better with the SS-LM than with LMA-U (P < 0.001). Blood staining was detected more frequently with the Cobra-PLA than with the LMA-U and SS-LM (P < 0.001), but there were no differences in airway morbidity.ConclusionThe LMA-U and SS-LM are easier to insert and cause less trauma than the Cobra-PLA, but the Cobra-PLA has a more effective seal than the LMA-U and better endoscopically determined anatomical position than the LMA-U and SS-LM.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…