Zhongguo Wei Zhong Bing Ji Jiu Yi Xue · Feb 2007
Randomized Controlled Trial Comparative Study[An auto control comparison of the use of ProSeal laryngeal mask airway and standard laryngeal mask airway for positive pressure ventilation].
- Cheng-wen Li, Fu-shan Xue, Peng Mao, Ya-chao Xu, Yi Liu, Guo-hua Zhang, Kun-peng Liu, and Hai-tao Sun.
- Department of Anesthesiology, Plastic Surgery Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100041, China.
- Zhongguo Wei Zhong Bing Ji Jiu Yi Xue. 2007 Feb 1;19(2):81-5.
ObjectiveTo compare the ProSeal laryngeal mask airway (PLMA) and the standard laryngeal mask airway (SLMA) for intermittent positive pressure ventilation (IPPV) in a randomized auto control design.MethodsFifty adult patients with American Society of Anesthesiologists (ASA) physical status 1-2, scheduled for elective plastic surgery under general anesthesia were recruited. After the routine intravenous anesthesia induction, the PLMA and the SLMA were inserted randomly in sequence into each patient and inflated to an intracuff pressure of 60 cm H(2)O (1 cm H(2)O=0.098 kPa), airway seal pressure and lung ventilation satisfaction were evaluated, and fiberoptic (FOB) scores of the cuff anatomic position were measured. The mean expired volume and the mean peak inspiratory pressure of five continuous breaths were calculated after IPPV with 10 ml/kg tidal volume was performed.ResultsWithout cuff inflation, airway seal pressure was higher with the PLMA than with the SLMA (P<0.05), and adequate or acceptable lung ventilation was obtained in 46 (92%) patients with the PLMA, but only 22 (44%) patients with the SLMA. When the air volume required to obtain an intracuff pressure of 60 cm H(2)O, adequate lung ventilation was obtained in 50 patients with the PLMA, but only 28 patients with the SLMA, and the inflation volume and sequential airway seal pressure were higher with the PLMA than with the SLMA (both P<0.05), and the airway seal pressure with the PLMA was not less than with the SLMA in each patient. The ventilation volume was higher with the PLMA than with the SLMA, except in 2 patients. The FOB score of the cuff position was lower with the PLMA than with the SLMA (P<0.05). The mean expired tidal volume and the mean peak inspiratory pressure were not significantly different between 29 patients with the PLMA and 21 patients with the SLMA for airway maintenance during operation (both P>0.05).ConclusionCompared with SLMA, PLMA can achieve a higher airway seal pressure and potentially isolate the glottis and the upper esophagus, and is safer and more effective for positive pressure ventilation.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.