• Anaesthesia · Nov 2010

    A simulation-based evaluation of two proposed alternatives to Luer devices for use in neuraxial anaesthesia.

    • T M Cook, S Payne, E Skryabina, D Hurford, E Clow, and A Georgiou.
    • Department of Anaesthesia, Royal United Hospital, Bath, UK. timcook007@googlemail.com
    • Anaesthesia. 2010 Nov 1;65(11):1069-79.

    AbstractThe National Patient Safety Agency has issued a Patient Safety Alert with the aim of eliminating Luer connectors from equipment for lumbar puncture and subarachnoid injections by 1 April 2011, and from all neuraxial and regional anaesthesia equipment in 2013. B-link (UK) Ltd and InterVene Ltd have produced non-Luer connectors for neuraxial devices: the Neurax and Spinalok respectively. Using an adult spinal simulator, 59 experienced clinicians performed neuraxial procedures using these devices and reported on specific performance characteristics and overall usability. Cross-connectivity between non-Luer and Luer connectors was also examined. The median (IQR [range]) overall assessment scores (0-10 scale) of usability for the standard, Neurax and Spinalok systems were 8 (8-9 [7-10]), 6 (5-7 [0-8]) and 7 (6-8 [1-9]) for spinal procedures and 8 (8-9 [6-10]), 7 (5-8 [1-9]) and 4 (3-6 [0-9]) for epidural procedures, respectively. Both study systems scored significantly lower than standard equipment for overall performance of spinal and epidural procedures, although the performance of non-Luer devices was mostly rated 'adequate' or better. Both non-Luer connectors could cross-connect with one or more Luer connectors. Following feedback to the manufacturers, both systems have been modified and cross-connectivity apparently has been eliminated. Our results indicate that clinicians may not find non-Luer devices immediately 'user-friendly'. More importantly, some cross-connectivity with Luer devices was possible. Our findings illustrate that introducing equipment that is fully compliant with the National Patient Safety Agency alert poses a significant challenge to manufacturers and clinicians. We conclude that before introducing any non-Luer device into widespread use, independent, formal evaluation should be carried out.© 2010 The Authors. Anaesthesia © 2010 The Association of Anaesthetists of Great Britain and Ireland.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.