-
Comparative Study
Diagnostic performance and therapeutic consequence of thromboelastometry activated by kaolin versus a panel of specific reagents.
- Ole Halfdan Larsen, Christian Fenger-Eriksen, Kirsten Christiansen, Jørgen Ingerslev, and Benny Sørensen.
- Centre for Haemophilia and Thrombosis, Aarhus University Hospital, Skejby, Denmark.
- Anesthesiology. 2011 Aug 1;115(2):294-302.
BackgroundThromboelastography/metry (TEG®; Haemoscope, Niles, IL/ROTEM®; Tem International GmbH, Munich, Germany) is increasingly used to guide transfusion therapy. This study investigated the diagnostic performance and therapeutic consequence of using kaolin-activated whole blood compared with a panel of specific TEM®-reagents to distinguish: dilutional coagulopathy, thrombocytopenia, hyperfibrinolysis, and heparinization.MethodsBlood was drawn from 11 healthy volunteers. Dilutional coagulopathy was generated by 50% dilution with hydroxyethyl starch 130/0.4 whereas thrombocytopenia (mean platelet count 20 ×10⁹/l) was induced using a validated model. Hyperfibrinolysis and heparin contamination were generated by tissue plasminogen activator 2 nM and unfractionated heparin 0.1U/ml, respectively. Coagulation tests were run on ROTEM® delta.ResultsKaolin-activated whole blood showed no differences between dilutional coagulopathy and thrombocytopenia (mean clotting time 450 s vs. 516 s, α-angle 47.1° vs. 41.5°, maximum clot firmness 35.0 mm vs. 34.2 mm, all P values ≥0.14). Hyperfibrinolysis specifically disclosed an increased maximum lysis (median: 100%, all P values less than 0.001), and heparin induced a distinctly prolonged clotting time (2283 s, all P values less than 0.02). The coagulopathies were readily distinguishable using a panel of TEM-reagents. In particular, dilutional coagulopathy was separated from thrombocytopenia using FIBTEM (maximum clot firmness 1.9 mm vs. 11.2 mm, P < 0.001). The run time of analysis to achieve diagnostic data was shorter applying a panel of TEM-reagents. A transfusion algorithm based on kaolin suggested platelets in case of dilutional coagulopathy, whereas an algorithm applying TEM-reagents suggested fibrinogen.ConclusionMonoanalysis with kaolin was unable to distinguish coagulopathies caused by dilution from that of thrombocytopenia. Algorithms based on the use of kaolin may lead to unnecessary transfusion with platelets, whereas the application of TEM-reagents may result in goal-directed fibrinogen substitution.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.