• Anesthesiology · Jul 2001

    Randomized Controlled Trial Comparative Study Clinical Trial

    Comparison of five experimental pain tests to measure analgesic effects of alfentanil.

    • M Luginbühl, T W Schnider, S Petersen-Felix, L Arendt-Nielsen, and A M Zbinden.
    • Department of Anesthesiology, University Hospital of Bern, Switzerland. martin.luginbuehl@dkf2.unibe.ch
    • Anesthesiology. 2001 Jul 1;95(1):22-9.

    BackgroundSeveral experimental pain models have been used to measure opioid effects in humans. The aim of the current study was to compare the qualities of five frequently used experimental pain tests to measure opioid effects.MethodsThe increase of electrical, heat, and pressure pain tolerance and the decrease of ice-water and ischemic pain perception was determined at baseline and at four different plasma concentrations of alfentanil (n = 7) administered as target controlled infusion or placebo (n = 7). A linear mixed-effects modeling (NONMEM) was performed to detect drug, placebo, and time effect as well as interindividual and intraindividual variation of effect.ResultsOnly the electrical, ice-water, and pressure pain tests are sensitive to assess a concentration-response curve of alfentanil. At a plasma alfentanil concentration of 100 ng/ml, the increase in pain tolerance compared with baseline was 42.0% for electrical pain, 22.2% for pressure pain, and 21.7% for ice-water pain. The slope of the linear concentration-response curve had an interindividual coefficient of variation of 58.3% in electrical pain, 35.6% in pressure pain, and 60.0% in ice-water pain. The residual error including intraindividual variation at an alfentanil concentration of 100 ng/ml was 19.4% for electrical pain, 6.1% for pressure pain, and 13.0% for ice-water pain. Electrical pain was affected by a significant placebo effect, and pressure pain was affected by a significant time effect.ConclusionElectrical, pressure, and ice-water pain, but not ischemic and heat pain, provide significant concentration-response curves in the clinically relevant range of 200 ng/ml alfentanil or lower. The power to detect a clinically relevant shift of the curve is similar in the three tests. The appropriate test(s) for pharmacodynamic studies should be chosen according to the investigated drug(s) and the study design.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.