Case Reports
Reconstruction after total en bloc sacrectomy for osteosarcoma using a custom-made prosthesis: a technical note.
- P Wuisman, O Lieshout, M van Dijk, and P van Diest.
- Departments of Orthopaedic Surgery and Pathology, Free University Hospital, Amsterdam, The Netherlands. orthop@azvu.nl
- Spine. 2001 Feb 15; 26 (4): 431439431-9.
Study DesignA report of an innovative technique to restore the lumbosacral junction after resection of primary highly malignant osteosarcoma of the sacrum involving the whole sacrum, soft tissues, and adjacent posterior parts of both iliac wings.ObjectivesTo describe the planning and design of a custom-made sacral prosthesis, the surgical technique, and clinical and functional outcome of the patient.Summary Of Background DataAlthough there have been case reports about reconstruction methods after total sacrectomy, to date, there has not been a reported clinical case of successful reconstruction using an individual designed prosthesis based on a three-dimensional real-sized model.MethodsA 42-year-old woman was referred with progressive neurologic impairment due to primary osteosarcoma of the sacrum invading surrounding structures. Based on a three-dimensional real-sized model, a detailed surgical plan was developed to assure safe, wide surgical margins. In addition, the model enabled design and testing of a custom-made sacral prosthesis, to provide stable lumbosacral reconstruction.ResultsAfter induction chemotherapy, a staged anteroposterior resection-reconstruction was successfully performed. After surgery, a superficial wound dehiscence was promptly treated. Within 3 weeks after surgery, mobilization began, and the adjuvant chemotherapy was continued. At the 36-month follow-up, the patient was disease free, had a stable, painless spinopelvic junction, and could walk short distances using ankle orthoses and crutches. Radiographs show complete incorporation of the pelvic grafts and unchanged position of the implant.ConclusionsIn planning and performing a total sacrectomy, including substantial parts of iliac wings, a three-dimensional real-sized model offers surgeons distinct advantages. Wide bony resection margins can be drawn on the model, and an individual custom-made prosthesis to re-establish spinopelvic continuity can be designed and tested before the intervention.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.