    The radiographic and imaging characteristics of porous tantalum implants within the human cervical spine.

    • A D Levi, W G Choi, P J Keller, J E Heiserman, V K Sonntag, and C A Dickman.
    • Department of Neurosurgery, University of Miami, Florida, USA.
    • Spine. 1998 Jun 1;23(11):1245-50; discussion 1251.

    Study DesignSeven cadaveric cervical spines were implanted with a porous tantalum spacer and a titanium alloy spacer, and their radiographic and imaging characteristics were evaluated.ObjectiveTo determine the radiographic characteristics of porous tantalum and titanium implants used as spacers in the cervical spine.Summary Of Background DataAnterior decompressive surgery of the disc space or the vertebral body creates a defect that frequently is repaired with autologous bone grafts to promote spinal fusion. Donor site morbidity, insufficient donor material, and additional surgical time have spurred the development of biomaterials to replace or supplement existing spinal reconstruction techniques. Although the promotion of a solid bony fusion is critical, the implanted biomaterial should be compatible with modern imaging techniques, should allow visualization of the spinal canal and neural foramina, and should permit radiographic assessment of bony ingrowth.MethodsCadaveric spines containing the implants were imaged with plain radiography, computerized tomography, and magnetic resonance imaging. The image distortion produced by the implants was determined qualitatively and quantitatively.ResultsThe tantalum and titanium spacers were opaque on plain radiographic films. On computed tomographic scans, more streak artifact was associated with the tantalum implants than with the titanium. On magnetic resonance imaging, the porous tantalum implant demonstrated less artifact than did the titanium spacer on T1- and T2-weighted spin echo and on T2*-weighted gradient-echo magnetic resonance images. Overall, the tantalum implant produced less artifact on magnetic resonance imaging than did the titanium spacer and therefore allowed for better visualization of the surrounding bony and neural structures.ConclusionThe material properties of titanium and porous tantalum cervical interbody implants contribute to their differential appearance in different imaging methods. The titanium implant appears to image best with computed tomography, whereas the porous tantalum implant produces less artifact than does the titanium implant on several magnetic resonance imaging sequences.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…