    Thermodilution cardiac output. Cold vs room temperature injectate and the importance of measuring the injectate temperature in the right atrium.

    • P G Berthelsen, N Eldrup, L B Nilsson, and J P Rasmussen.
    • Department of Anesthesiology, Gentofte Hospital, University of Copenhagen, Denmark. prge@gentoftehosp.kbhamt.dk
    • Acta Anaesthesiol Scand. 2002 Oct 1;46(9):1103-10.

    BackgroundThe feasibility of thermodilution cardiac output measurements with the more convenient room temperature thermal indicator instead of cold injectates has been repeatedly investigated. However, the issue has not been addressed with the appropriate statistical approach advocated by Altman and Bland. Furthermore, we wished to determine if the incorporation of a second thermistor in the thermodilution catheter, to measure the temperature of the thermal indicator where it is delivered into the right atrium/superior caval vein, would result in more precise cardiac output measurements.MethodsFifty patients were randomized to receive a single or dual thermistor pulmonary artery thermodilution catheter. Cardiac output was calculated as the average of four injections of 10 ml of isotonic saline. Precision (2 x SD of differences in replicate measurements) for the two catheters and injectate temperatures, and bias and limits of agreement between measurements, with cold and room temperature injectates, were determined.ResultsPrecision was (0 degrees C) 0.42 l/min and (20 degrees C) 0.90 l/min, and bias and limits of agreement -0.83 l/min and -1.93-0.27 l/min for the single thermistor catheter. For the dual thermistor system precision was (0 degrees C) 0.34 l/min and (20 degrees C) 0.58 l/min. Bias and limits of agreement were -0.03 l/min and -0.61-0.55 l/min.ConclusionThe second thermistor is redundant if cold injectates are used. If one wishes to use room temperature injectates the single thermistor system is inadequate. A dual thermistor catheter is, on the other hand, acceptable.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.