• Spine · Oct 1999

    Comparative Study

    Revision strategies for salvaging or improving failed cylindrical cages.

    • P C McAfee, B W Cunningham, G A Lee, C M Orbegoso, C J Haggerty, I L Fedder, and S L Griffith.
    • Scoliosis and Spine Center, Union Memorial Hospital Baltimore, Maryland, USA.
    • Spine. 1999 Oct 15;24(20):2147-53.

    Study DesignThis is a review of 20 patients who experienced failure of threaded interbody fusion cages and underwent surgical correction.ObjectiveTo review the causes and possible treatment strategies for failed cylindrical cages.Summary Of Background DataIntraoperative complications have been described in the past; however, management of the postoperative patient with failure of interbody fusion devices has not been described.MethodsIn 20 patients with failed threaded titanium fusion cages (18 Bagby and Kuslich Devices [BAK; Sulzer-Spine Tech, Minneapolis, MN], 2 Ray Threaded Fusion Cages [Ray TFC; Surgical Dynamics, Norwalk, CT) who underwent revision surgery, all had failure before successful arthrodesis was achieved. Eight of the original titanium cages had been inserted anteriorly (7 laparoscopically), and 12 had been inserted for posterior interbody lumbar fusion. Before the revision surgery, five of the implants were thought to be solid by the referring surgeon, but pseudarthrosis was clearly present in all. In addition, 14 other explanted BAK devices were subjected to undecalcified histologic preparation, quantitative histomorphometry, and histopathologic analysis.ResultsThe average length of time before revision surgery (implant duration) was 31.8 weeks (range, 1-156 weeks). The most common revision procedure was posterior exploration of the symptomatic nerve root with foraminotomy for unrecognized lateral recess stenosis (11 cases) or excision of iatrogenically herniated intervertebral disc fragments (4 cases). However, four cages inserted through posterior exposure during an interbody lumbar fusion procedure had to be removed because of migration into the spinal canal. In nine cases posterior pedicle screw instrumentation was necessary in addition to posterolateral fusion using iliac crest bone grafting.ConclusionsAll 20 cages failed because of surgical technique rather than an intrinsic defect in fusion cage technology. The factors associated with failure of the original insertion procedure were failure to achieve adequate distraction of the anulus fibrosis; undersized cages, especially when placed through the posterior interbody lumbar fusion approach; cerebrospinal fluid leakage or pseudomeningocele; Type 2 diabetes mellitus; the use of local bone graft rather than iliac crest inside the cage; anterior insertion in an excessively lateral position resulting in symptoms of a far lateral disc herniation; and failure to identify the spinal midline during an anterior approach.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…