    Weekly ventilator circuit changes. A strategy to reduce costs without affecting pneumonia rates.

    • D Hess, E Burns, D Romagnoli, and R M Kacmarek.
    • Department of Respiratory Care, Massachusetts General Hospital, Boston 02114, USA.
    • Anesthesiology. 1995 Apr 1;82(4):903-11.

    BackgroundMechanical ventilator circuits are commonly changed at 48-h intervals. This frequency may be unnecessary because ventilator-associated pneumonia often results from aspiration of pharyngeal secretions and not from the ventilator circuit. We compared the ventilator-associated pneumonia rates and costs associated with 48-h and 7-day circuit changes.MethodsVentilator circuits were changed at 48-h intervals during the control period (November 1992 to April 1993) and at 7-day intervals during the study period (June 1993 to November 1993). Nosocomial pneumonias were prospectively identified using the criteria of the Centers for Disease Control and Prevention. The annual cost difference of changing circuits at 48-h and 7-day intervals was calculated using the distribution of ventilator days for the control and study periods.ResultsThere were 1,708 patients, 9,858 ventilator days, and a pneumonia rate of 9.64 per 1,000 ventilator days in the control group (48-h circuit changes). There were 1,715 patients, 9,160 ventilator days, and 8.62 pneumonias per 1,000 ventilator days when circuits were changed at 1-week intervals (study group). Using a logistic regression model, there were significantly greater odds of developing a ventilator-associated pneumonia in surgical patients (odds ratio 1.77, P = 0.02) and patients in critical care units (odds ratio 1.54, P = 0.05), but no significant risk of ventilator-associated pneumonia in patients in whom circuits were changed at 1-week intervals (odds ratio 0.82, P = 0.22). Changing circuits at 7-day intervals resulted in a 76.6% ($111,530) reduction in the annual cost for materials and salaries.ConclusionsWe found no difference in pneumonia rates with ventilator circuit changes at 48-h and 7-day intervals. Ventilator circuits can be safely changed at weekly intervals, resulting in large cost savings.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.