    Differences among forced-air warming systems with upper body blankets are small. A randomized trial for heat transfer in volunteers.

    • T Perl, A Bräuer, A Timmermann, F Mielck, W Weyland, and U Braun.
    • Department of Anaesthesiology, Emergency and Intensive Care Medicine, University of Goettingen, Goettingen, Germany. tperl@gwdg.de
    • Acta Anaesthesiol Scand. 2003 Oct 1; 47 (9): 1159-64.

    BackgroundForced-air warming is known as an effective procedure in prevention and treatment of perioperative hypothermia. Significant differences have been described between forced-air warming systems in combination with full body blankets. We investigated four forced-air warming systems in combination with upper body blankets for existing differences in heat transfer.MethodsAfter approval of the local Ethics Committee and written informed consent, four forced-air warming systems combined with upper body blankets were investigated in a randomized cross-over trial on six healthy volunteers: (1) BairHugger trade mark 505 and Upper Body Blanket 520, Augustine Medical; (2) ThermaCare trade mark TC 3003, Gaymar trade mark and Optisan trade mark Upper Body Blanket, Brinkhaus; (3) WarmAir trade mark 134 and FilteredFlow trade mark Upper Body Blanket, CSZ; and (4) WarmTouch trade mark 5800 and CareDrape trade mark Upper Body Blanket, Mallinckrodt. Heat transfer from the blanket to the body surface was measured with 11 calibrated heat flux transducers (HFTs) with integrated thermistors on the upper body. Additionally, the blanket temperature was measured 1 cm above the HFT. After a preparation time of 60 min measurements were started for 20 min. Mean values were calculated over 20 min. The t-test for matched pairs with Bonferroni-Holm-correcture for multiple testing was used for statistical evaluation at a P-level of 0.05. The values are presented as mean+/-SD.ResultsThe WarmTouch trade mark blower with the CareDrape trade mark blanket obtained the best heat flux (17.0+/-3.5 W). The BairHugger trade mark system gave the lowest heat transfer (8.1+/-1.1 W). The heat transfer of the ThermaCare trade mark system and WarmAir trade mark systems were intermediate with 14.3+/-2.1 W and 11.3+/-1.0 W.ConclusionsBased on an estimated heat loss from the covered area of 38 W the heat balance is changed by 46.1 W to 55 W by forced-air warming systems with upper body blankets. Although the differences in heat transfer are significant, the clinical relevance of this difference is small.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.