-
Anesthesia and analgesia · Nov 2008
The dynamic relationship between end-tidal sevoflurane concentrations, bispectral index, and cerebral state index in children.
- Ricardo Fuentes, Luis I Cortínez, Michel M R F Struys, Alejandro Delfino, and Hernán Muñoz.
- Departamento de Anestesiología, Hospital Clínico U. Católica, Marcoleta 367, Santiago, Chile.
- Anesth. Analg. 2008 Nov 1;107(5):1573-8.
BackgroundTo guide anesthetic administration with electroencephalogram monitors in children, an adequate characterization of the anesthetic effect measured by these monitors in this population is needed. We sought to quantify and compare the dynamic profile of sevoflurane's effect measured with the cerebral state index (CSI) and the bispectral index (BIS) in children.MethodsFifteen healthy children, aged 3-15 yr, scheduled to undergo minor surgery were prospectively studied. During the simultaneous recording of CSI and BIS, the sevoflurane vaporizer was set at 6 vol % for 5 min and then decreased. End-tidal concentrations (C(ET)) were measured. The C(ET)-sevoflurane effect-site concentration equilibration and pharmacodynamics were modeled. Goodness of fit between models was compared. Data are typical value (coefficient of variation).ResultsWithin the anesthetic depth range studied, the rate of change of sevoflurane's effect expressed as the effect-site equilibration half-life (t(1/2) k(e0)) was slower with the CSI [2.0 (14) min] than with BIS [1.2 (53) min] (P < 0.05). The estimated baseline effect of BIS and CSI before sevoflurane administration (E(0)) was 84 (39) for CSI and 87 (7) for BIS (NS). The sensitivity to sevoflurane hypnotic effect expressed in the C(50) [steady-state C(ET) eliciting half of the maximum response (E(max))] was 2.1 (68) % with CSI and 2.1 (16)% with BIS (NS). The E(max) with CSI 45 (0) was higher than that with BIS 27 (39) (P < 0.05). The population prediction error was significantly better for BIS (-0.7 +/- 26.9) than for CSI (-3.0 +/- 178.6) (P < 0.05).ConclusionsIn children, the t(1/2) k(e0) of sevoflurane and the pharmacodynamics of sevoflurane were quantified and the results were entirely dependent on the monitor used to measure its hypnotic effect. Within the anesthetic depth range studied, the rate of change of sevoflurane's effect was slower with the CSI. To adequately guide sevoflurane administration with these monitors in children, these differences should be considered.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.