JACC Cardiovasc Interv · Feb 2009
Late results after percutaneous closure of patent foramen ovale for secondary prevention of paradoxical embolism using the amplatzer PFO occluder without intraprocedural echocardiography: effect of device size.
- Andreas Wahl, Tony Tai, Fabien Praz, Markus Schwerzmann, Christian Seiler, Krassen Nedeltchev, Stephan Windecker, Heinrich P Mattle, and Bernhard Meier.
- Department of Cardiology, University Hospital, Bern, Switzerland.
- JACC Cardiovasc Interv. 2009 Feb 1;2(2):116-23.
ObjectivesWe sought to assess the safety and clinical efficacy of patent foramen ovale (PFO) closure under fluoroscopic guidance only, without intraprocedural echocardiography.BackgroundPercutaneous PFO closure has been shown to be safe and feasible using several devices. It is generally performed using simultaneously fluoroscopic and transesophageal or intracardiac echocardiographic guidance. Transesophageal echocardiography requires sedation or general anesthesia and intubation to avoid aspiration. Intracardiac echocardiography is costly and has inherent risks. Both lengthen the procedure. The Amplatzer PFO Occluder (AGA Medical Corporation, Golden Valley, Minnesota) can be safely implanted without echocardiographic guidance.MethodsA total of 620 patients (51 +/- 12 years; 66% male) underwent PFO closure using the Amplatzer PFO Occluder for secondary prevention of presumed paradoxical embolism. Based on size and mobility of the PFO and the interatrial septum, an 18-mm device was used in 50 patients, a 25-mm device in 492, and a 35-mm device in 78.ResultsAll procedures were successful, with 5 procedural complications (0.8%): 4 arteriovenous fistulae requiring elective surgical correction, and 1 transient ischemic attack. Contrast transesophageal echocardiography at 6 months showed complete closure in 91% of patients, whereas a minimal, moderate, or large residual shunt persisted in 6%, 2%, and 1%, respectively. During a mean follow-up period of 3.0 +/- 1.9 years (median: 2.6 years; total patient-years: 1,871), 5 ischemic strokes, 8 transient ischemic attacks, and no peripheral emboli were reported. Freedom from recurrent ischemic stroke, transient ischemic attack, or peripheral embolism was 99% at 1 year, 99% at 2 years, and 97% at 5 years.ConclusionsThe Amplatzer PFO Occluder affords excellent safety and long-term clinical efficacy of percutaneous PFO closure without intraprocedural echocardiography.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.