• J Neurosurg Anesthesiol · Apr 1999

    Randomized Controlled Trial Comparative Study Clinical Trial

    Effects of two calculated plasma sufentanil concentrations on the hemodynamic and bispectral index responses to Mayfield head holder application.

    • P Hans, J F Brichant, P Y Dewandre, J D Born, and M Lamy.
    • University Department of Anesthesia and Intensive Care Medicine, CHR de la Citadelle, CHU Liege, Belgium.
    • J Neurosurg Anesthesiol. 1999 Apr 1;11(2):81-5.

    AbstractThe effects of two calculated plasma sufentanil (SUF) concentrations on the hemodynamic and bispectral index (BIS) responses to Mayfield head holder (MH) application were studied in 20 patients scheduled for intracranial surgery. Premedication consisted of hydroxyzine, alprazolam, and atropine given orally 1 hour before surgery. Anesthesia was provided with propofol (PPF) and SUF using a target-controlled infusion device. Patients were randomly assigned to one of two groups according to calculated plasma concentrations: 3 microg/mL(-1) of PPF and 0.5 ng/mL(-1) of SUF in group I (GI) and 3 microg/mL(-1) of PPF and 1 ng/mL(-1) of SUF in group II (GII). The MH was fixed 33.0+/-6.6 minutes (mean +/- SD) after induction. Systolic (SAP), diastolic (DAP), and mean arterial pressure (MAP) as well as heart rate (HR) and BIS were recorded 1 minute before pinning (baseline) as well as 1 minute (P1), 2 minutes (P2), and 3 minutes (P3) after pinning. Multivariate repeat-measured analyses of variance were applied to the baseline-subtracted measurements of hemodynamic and BIS values. Groups were compared using the Student's t test, and P < .05 was considered to be statistically significant. Patients' characteristics, baseline hemodynamic values, and BIS values were similar in both groups. A significant overall time effect was observed for all variables, but no significant overall SUF effect was detected. Increases in SAP, MAP, DAP, and HR did not differ significantly between groups. The increase in hemodynamic variables did not exceed 20% of baseline value in either group. In contrast, at P1, the increase in BIS over the baseline value was significantly higher in GI (15.0+/-7.9) than in GII (6.7+/-6.5). In conclusion, MH application was associated with a significant, although not clinically relevant, increase in hemodynamic variables whatever the calculated plasma SUF concentration (0.5 or 1.0 ng/mL(-1)). In contrast, the increase in BIS observed at pinning was significantly higher in patients with the lowest calculated plasma SUF concentrations. This suggests that the BIS response to noxious stimulation is modulated by the analgesic regimen.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.