• Anaesthesia · Nov 2012

    Comparative Study

    A clinical evaluation of four non-Luer spinal needle and syringe systems.

    • S M Kinsella, A Goswami, C Laxton, L Kirkham, N Wharton, and M Bowen.
    • St Michael's Hospital, University Hospitals Bristol NHS Foundation Trust, Bristol, UK. stephen.kinsella@uhbristol.nhs.uk
    • Anaesthesia. 2012 Nov 1;67(11):1217-24.

    AbstractWe performed an evaluation of non-Luer spinal devices supplied by four manufacturers or suppliers: Polymedic; Pajunk; Sarstedt; and Smiths. For each supplier, 100 evaluations were performed using a 25-G 90-mm spinal needle, 3-ml syringe, 5-ml syringe and filter needle; for comparison, 100 evaluations were performed with our standard Luer equipment. The non-Luer devices were associated with more qualitative problems compared with the Luer devices, for example, poor feel of dural puncture (9-32% vs 10%, respectively), poor observation of cerebrospinal fluid in the hub (3-27% vs 0%), and connection problem of the syringe to the spinal needle (7-33% vs 0%). There was also more frequent failure to achieve the spinal injection due to equipment-related causes (4-7% vs 0%, respectively). Median (IQR [range]) numeric satisfaction scores for the spinal needles were: Luer 10 (9-10 [7-10]); Polymedic 7 (4-8 [0-10]; Pajunk 7 (5-8 [0-10]); Sarstedt 7 (6-8 [0-10]); and Smiths 9 (7-10 [0-10]) (p<0.0001). Satisfaction scores for all spinal equipment were: Luer 10 (9-10 [5-10]); Polymedic 8 (6-8 [0-10]); Pajunk 7 (5-7 [1-9]); Sarstedt 8 (6-8 [0-10]); and Smiths 8 (8-9 [2-10]) (p<0.0001). Between 21% and 75% of non-Luer evaluations were rated with satisfaction worse than the usual Luer needle compared with 0-10% rated better, depending on the needle type. Between 22% and 76% of non-Luer evaluations were rated with satisfaction worse than the usual Luer equipment compared with 0-14% rated better. Specific concerns included poor feel of tissue planes and observation of cerebrospinal fluid (Polymedic), difficulty with connection of the syringe to the spinal needle and trocar removal (Pajunk), poor feel of tissue planes and needle flexibility (Sarstedt) and difficulty with connection of the syringe to the spinal needle (Smiths). We could not demonstrate a short-term learning curve for the new devices. Decisions on purchasing and implementation of the new non-Luer equipment will have to acknowledge that clinicians may have greater technical problems and reduced satisfaction compared with the current equipment.Anaesthesia © 2012 The Association of Anaesthetists of Great Britain and Ireland.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.