• Am J Emerg Med · May 2014

    Randomized Controlled Trial Comparative Study

    The comparison of heparinized insulin syringes and safety-engineered blood gas syringes used in arterial blood gas sampling in the ED setting (randomized controlled study).

    • Sevcan Baki Baskın, Neşe Çolak Oray, Sedat Yanturalı, and Başak Bayram.
    • Department of Emergency Medicine, School of Medicine, Dokuz Eylul University, Konak, Turkey; Department of Emergency Medicine, Ardahan State Hospital, Ardahan, Turkey. Electronic address: sevcan_sevcan@mynet.com.
    • Am J Emerg Med. 2014 May 1;32(5):432-7.

    IntroductionThe arterial blood gas measurement process is a painful and invasive procedure, often uncomfortable for both the patient and the physician. Because the patient-related factors that determine the difficulty of the process cannot be controlled, the physician-related factors and blood gas measurement techniques are a modifiable area of improvement that ought to be considered. Many hospitals use insulin syringes or syringes washed with heparin for the purpose of blood gas measurement because they do not have blood gas-specific syringes. In this prospective cross-sectional study, we aimed to compare safety-engineered blood gas syringes and conventional heparinized syringes used during the arterial blood gas extraction process in terms of ease of operation, the physician-patient satisfaction, laboratory appropriateness, and complications.MethodsOur study included patients whose arterial blood gas needed to be measured in the emergency department and who agreed to participate in the study. Patients were randomly divided into 2 groups. The arterial blood gas of the patients from the first group was measured by using conventional heparinized syringes, whereas safety-engineered blood gas syringes were used to measure the arterial blood gas of the patients from the second group. The groups were compared in terms of demographic data, the number of attempts, the physician and patient satisfaction, early and late-term complications, and laboratory appropriateness of the taken sample.ResultsA total of 550 patients were included in our study in a 2-month study period. There were no significant differences between patients in terms of sex, age, weight, height, body mass index, and wrist circumference. In addition, the number of attempts (P=.489), patients' pain level during the procedure (P=.145), and the degree of difficulty of the procedure according to the patient (P=.109) and physician (P=.554) were not significantly different between the groups. After arterial blood gas extraction procedure, 115 patients (20.9%) developed complications. In the conventional heparinized syringe group, the complication rate (n=69; 25.1%) was significantly higher compared with the group that used safety-engineered blood gas syringes (n=46; 16%; P=.0211). Localized pain, which is one of the most common early complications, was more frequent in the conventional heparinized syringe group (19.3%). Complications in women (P=.003) and local pain (P=.01) developed lesser in the second group that used safety-engineered blood gas syringes, and the patient-physician satisfaction was higher in that group, as well. In the evaluation 48 hours after the procedure, the ratios of infection and local hematoma were higher in the conventional heparinized syringe group (P=.0213 and P < .0001).ConclusionIn this study, we did not find any significant differences between the conventional heparinized syringes and safety-engineered blood gas syringes in terms of ease of operation, physician and patient satisfaction, and appropriateness of the taken sample. However, patients whose arterial blood gas was extracted by using safety-engineered blood gas syringes felt less pain and experienced fewer infections and hematomas at their puncture site.Copyright © 2014 Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.