    Determining epidural catheter location using nerve stimulation with radiological confirmation.

    • B C Tsui, C Guenther, D Emery, and B Finucane.
    • Department of Anesthesiology and Pain Medicine, University of Alberta Hospitals, Edmonton, Canada. btsui@pop.srv.ualberta.ca
    • Reg Anesth Pain Med. 2000 May 1; 25 (3): 306-9.

    Background And ObjectivesThe use of epidural stimulation to confirm epidural catheter placement has been shown. This case report describes the benefits and problems of using the epidural stimulation test to confirm epidural catheter placement and provides supporting evidence for these observations using radiological imaging.Case ReportMethodsA nerve stimulator was connected to the proximal end of an epidural catheter via an adapter. The cathode lead was connected to the adapter. The anode lead was connected to an electrode placed on the upper extremity as a grounding site. Using 1 to 10 mA current, a segmental motor response indicated that the catheter was in the epidural space. The absence of a motor response indicated that it was not.CasesIn the first patient, the new test predicted subcutaneous epidural catheter placement, which was subsequently confirmed radiologically. In the second patient, the catheter tip was found to be lying near a nerve root, which was again confirmed radiologically. In the third case, a negative test was initially observed with only local muscle movement over the biceps area (T2). After relocation of the grounding electrode to the lower extremity, segmental intercostal muscle movement (T4-5 level) was observed. The catheter placement was radiologically shown to be in the T4-5 region.ConclusionThis report illustrates some of the potential benefits and problems of using the nerve stimulation test to confirm epidural catheter placement, with radiological verification.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.