• Ann. Thorac. Surg. · Feb 2004

    Comparative Study

    Semirigid partial annuloplasty band allows dynamic mitral annular motion and minimizes valvular gradients: an echocardiographic study.

    • Ram Sharony, Paul C Saunders, Ambika Nayar, Eileen McAleer, Aubrey C Galloway, Julie Delianides, Charles F Schwartz, Robert M Applebaum, Itzhak Kronzon, Stephen B Colvin, and Eugene A Grossi.
    • Division of Cardiothoracic Surgery, Department of Surgery, New York University School of Medicine, New York, New York, USA.
    • Ann. Thorac. Surg. 2004 Feb 1;77(2):518-22; discussion 522.

    BackgroundTraditional mitral annuloplasty devices include both rigid rings, which restrict annular motion, and soft rings and bands, which can locally deform. Conflicting data exist regarding their impact on annular dynamics. We studied mitral annuloplasty with a semirigid partial band and with a nearly complete rigid ring.MethodsIntraoperative three-dimensional transesophageal echocardiograms (n = 14) and predischarge transthoracic echocardiograms were retrospectively analyzed in patients undergoing mitral valve repair for degenerative disease with either a rigid ring (n = 77) or a semirigid partial band (n = 38). Each transesophageal echocardiogram was analyzed with TomTec three-dimensional software to produce cardiac cycle frame planimetry and to measure device geometry. Actual device sizes provided reference dimensions. Blinded analysis of Doppler data from transthoracic echocardiograms was performed.ResultsValidation of the quantitative transesophageal echocardiogram methodology revealed a 1.3% +/- 0.3% (mean +/- standard error of the mean) underestimation of actual linear dimension. With the semirigid partial band, systolic valve orifice area and intertrigonal distance decreased from 6.14 +/- 0.37 to 5.55 +/- 0.24 cm(2) (-9.6%; p = 0.01) and from 2.69 +/- 0.08 to 2.55 +/- 0.13 cm (-5.2%; p = 0.03), respectively. Systolic anterior-posterior distance decreased from 2.1 +/- 0.10 to 1.95 +/- 0.06 cm (-7.1%; p = 0.01) compared with diastole. In contrast, rigid ring orifice area was unchanged (4.12 +/- 0.15 to 4.10 +/- 0.16 cm(2); -0.5%; p = 0.48) during the cardiac cycle. Transthoracic echocardiography revealed significantly lower mitral inflow gradients with semirigid partial band (mean gradients compared with rigid ring, 4.0 +/- 0.3 versus 5.0 +/- 0.3 mm Hg; p = 0.02; peak gradients, 8.9 +/- 0.5 versus 11.1 +/- 0.5 mm Hg; p = 0.01).ConclusionsThree-dimensional transesophageal echocardiographic measurements of annular dynamics are valid and reliable when discrete annuloplasty devices are present. In contrast to the rigid ring, the semirigid partial band permits more physiologic geometric changes and is associated with lower postoperative mitral valve gradients.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.