Randomized Controlled Trial Clinical Trial
A prospective evaluation of clinical tests for placement of laryngeal mask airways.
- S Joshi, R R Sciacca, D R Solanki, W L Young, and M M Mathru.
- Department of Anesthesiology, Columbia University College of Physicians and Surgeons, New York, New York, USA.
- Anesthesiology. 1998 Nov 1;89(5):1141-6.
BackgroundReliable tests of correct anatomic placement of the laryngeal mask airway (LMA) may enhance safety during use and minimize the need for fiberoptic instrumentation during airway manipulation through the device. This study assessed the correlation between the outcomes of nine clinical tests to place the LMA and the anatomic position of the device as graded on a standard fiberoptic scale.MethodsDuring 150 anesthetics, the outcome of nine clinical tests of correct placement was individually scored as satisfactory (positive) or unsatisfactory (negative) for clinical use of the LMA. Anatomic placement was assessed (by fiberoptic evaluation) by an anesthesiologist, who was blinded to the placement of the device, as grade 1, vocal cords not seen; grade 2, cords plus the anterior epiglottis seen; grade 3, cords plus the posterior epiglottis seen; and grade 4, only vocal cords seen. The outcomes of clinical tests were correlated with fiberoptic grade.ResultsTests that correlated with the fiberoptic grade were the ability to generate an airway pressure of 20 cm water, the ability to ventilate manually, a black line on the LMA in midline, anterior movement of the larynx, outward movement of the LMA on inflation of the cuff, and movements of the reservoir bag with spontaneous breathing. Two tests, ability to generate airway pressure of 20 cm water and ability to ventilate manually, correlated with fiberoptic grades 4 and 3 combined (i.e., the epiglottis was supported by the LMA) and grade 2 (the epiglottis was not supported by the LMA). Tests with poor correlation with fiberoptic grade were the presence of resistance at the end of insertion, inability to advance LMA after inflation of the cuff, and presence of a capnographic trace.ConclusionsThe outcome of clinical tests correlates with the anatomic placement of LMAs, as judged by fiberoptic examination. Two tests that best correlated with the fiberoptic grade were the ability to generate airway pressure of 20 cm water and the ability to ventilate manually.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.