• Arch Orthop Trauma Surg · Jan 1993

    Stress transfer at the femoral bone/bone cement interface as a function of the cement thickness.

    • V Jansson, B Heimkes, and M Zimmer.
    • Orthopädische Klinik und Poliklinik, Ludwig-Maximilians-Universität, München, Germany.
    • Arch Orthop Trauma Surg. 1993 Jan 1;112(2):65-8.

    AbstractWhen a cement canal prosthesis is used as the femoral component in total hip replacement (THR), the penetration depth of the bone cement can be varied according to the cement implantation pressure. Using experimental data which give a relation between the pressure applied to the cement at implantation and the resulting shape of the cement layer, a three-dimensional finite element study was performed to calculate the stress distribution at the bone/bone cement interface. The calculations show that the interface stresses increase with increasing depth of penetration by the cement layer. The explanation of this effect is that as the bone cement penetrates further into the cancellous bone, the cancellous bone is stiffened and can no longer act as a soft interposition between cortical bone and bone cement. From these results and from the clinical requirement that as little bone as possible be destroyed in any kind of allo-arthroplasty, we conclude that the penetration depth of bone cement into cancellous bone in THR should be minimized to the depth necessary in order to achieve sufficient initial stability of the implant. The results show that a cement-canal prosthesis meets these requirements if a cement implantation pressure of 1.0 bar is used.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?

    User can't be blank.

    Content can't be blank.

    Content is too short (minimum is 15 characters).

    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…