• Anesthesiology · Jun 1998

    Randomized Controlled Trial Clinical Trial

    Causes and prediction of maldistribution during continuous spinal anesthesia with isobaric or hyperbaric bupivacaine.

    • P Biboulet, X Capdevila, P Aubas, J Rubenovitch, J Deschodt, and F d'Athis.
    • Department of Anesthesiology and Critical Care, Lapeyronie University Hospital, Montpellier, France.
    • Anesthesiology. 1998 Jun 1;88(6):1487-94.

    BackgroundMany cases of cauda equina syndrome after maldistribution of local anesthetics during continuous spinal anesthesia have been reported. In experiments, a caudad route of catheter travel and the use of hyperbaric agents have been shown to induce these limited blocks. The aim of this clinical study was to verify this hypothesis and seek a predictive factor for the maldistribution of bupivacaine.MethodContinuous spinal anesthesia via a 19-gauge end port spinal catheter was performed in 80 elderly patients randomly assigned to receive either isobaric or hyperbaric solutions. Successive injections of 2.5 mg bupivacaine were performed at 5-min intervals until a sensory level at or cranial to T8 was obtained. Maldistribution was defined by a sensory level caudal to T12 despite a total dose of 17.5 mg of either isobaric or hyperbaric bupivacaine. After surgery, all catheters were injected with contrast media and examined radiographically.ResultsThe frequency of maldistribution was not significantly different in the isobaric and hyperbaric groups. A caudally oriented catheter tip was found to be a major cause of maldistribution (P < 10(-5)). A thoracic sensory level could be reached in all patients presenting a limited block by simply changing the baricity of the bupivacaine, the position of the patient, or both. The sensory level obtained 10 min after the first injection of 2.5 mg isobaric or hyperbaric bupivacaine was found to be a predictive factor of maldistribution.ConclusionsHyperbaric solutions do not appear to be a clinical factor in the development of limited block. The principle factor causing the maldistribution of bupivacaine is the caudal orientation of the tip of the end-hole catheter rather than its level or the route of catheter travel.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…