• J Clin Anesth · Jun 2016

    Intrinsic positive end-expiratory pressure during ventilation through small endotracheal tubes during general anesthesia: incidence, mechanism, and predictive factors.

    • Marco Gemma, Elisa Nicelli, Daniele Corti, Assunta De Vitis, Nicolò Patroniti, Giuseppe Foti, Maria Rosa Calvi, and Luigi Beretta.
    • Anesthesia and Intensive Care, Department of Anesthesiology, San Raffaele Scientific Institute, via Olgettina 60, 20132 Milan, Italy. Electronic address: gemma.marco@hsr.it.
    • J Clin Anesth. 2016 Jun 1; 31: 124-30.

    Study ObjectiveTo assess the safety of mechanical ventilation and effectiveness of extrinsic positive end-expiratory pressure (PEEP) (PEEPe) in improving peripheral oxygen saturation (SpO2) during direct microlaryngeal laser surgery; to assess the incidence, amount, and nature (dynamic hyperinflation or airflow obstruction) of ensuing intrinsic PEEP (PEEPi); and to find a surrogate PEEPi indicator.DesignQuasiexperimental.SettingS. Raffaele Hospital (Milano), November 2009 to December 2010.PatientsFifty-two adults scheduled for direct microlaryngeal laser surgery. Exclusion criterion is pregnancy.InterventionsTwenty-one percent O2 mechanical ventilation through 4.5- to 5.5-mm internal diameter endotracheal tubes; in 29 patients, after measurement of PEEPi, an identical amount of PEEPe was added; and PEEPi.MeasurementsSpO2, peak (Pawpeak) and plateau (Pawplateau) airway pressure, and end-expiratory carbon dioxide were measured every 5 minutes. Respiratory compliance (Crs) was computed. PEEPi was measured (end-expiratory occlusion method).Main ResultsPEEPi ≥5 cm H2O occurred in 14 patients (27%) after intubation, in 16 (30%) at the beginning, and in 14 (27.3%) at the end of surgery. Thirty-one patients (59.4%) exhibited PEEPi ≥5 cm H2O on at least 1 time point. PEEPi at the beginning of surgery was positively correlated with Pawplateau, Crs, tidal volume, and body mass index. Body mass index was the only predictor for the occurrence of PEEPi ≥5 cm H2O. At the beginning of surgery, the Pawplateau receiver operating characteristic curve predicting PEEPi ≥5 cm H2O had area under the receiver operating characteristic curve of 0.85; best cutoff value of 15.5 cm H2O (sensitivity, 88.9%; specificity, 75%; correctly classified cases, 86.1%). When PEEPe was applied, in 23 cases (82.1%), total PEEP equaled PEEPe+ PEEPi; in 3 (10.7%), it was lower; and in 2 (7.1%), it was higher. Application of PEEPe increased SpO2 (P< .05) and Crs (P< .05).ConclusionsDuring ventilation through small endotracheal tubes, PEEPi (mostly due to dynamic hyperinflation) is common. Hemodynamic complications, barotrauma, and O2 desaturation (reversible with PEEPe) are rare. Pawplateau provided by ventilators is useful in suspecting and monitoring the occurrence of PEEPi and allows detection of lung overdistension as PEEPe is applied.Copyright © 2016 Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…