• Anesthesiology · May 1997

    Clinical Trial

    Bronchoscopy via a redesigned Combitube in the esophageal position. A clinical evaluation.

    • P Krafft, M Röggla, P Fridrich, G J Locker, M Frass, and J L Benumof.
    • Department of Anesthesiology and General Intensive Care, University of Vienna, Austria. Peter.Krafft@akh-wien.ac.at
    • Anesthesiology. 1997 May 1; 86 (5): 1041-5.

    BackgroundThe esophageal-tracheal Combitube (Kendall-Sheridan Catheter Corp., Argyle, NY) is an effective device for providing adequate gas exchange. However, tracheal suctioning is impossible with the Combitube placed in the esophageal position. To eliminate this disadvantage, the Combitube was redesigned by creating an enlarged hole in the pharyngeal lumen that allows fiberoptic access, tracheal suctioning, and tube exchange over a guide wire.MethodsThe two anterior, proximal perforations of regular Combitubes were replaced by a larger, ellipsoid-shaped hole. After the study was approved by the institutional review board, 20 patients with normal airways (Mallampati I or II) were studied. During general anesthesia, patients were esophageally intubated with the Combitube. A flexible bronchoscope was inserted and guided via the modified hole and glottic opening down the trachea. For the replacement procedure, a J tip guide wire was introduced through the bronchoscope. The bronchoscope and the Combitube were removed and a standard endotracheal tube was advanced over a guide catheter.ResultsBronchoscopic evaluation of the trachea and guided replacement of the Combitube by an endotracheal tube was successful in all 20 study patients. The average time needed to perform airway exchange was 90 +/- 20 s (mean +/- SD). Arterial oxygen saturation and end-tidal carbon dioxide levels remained normal in all patients. No case of laryngeal trauma was observed during intubation or the airway exchange procedure.ConclusionsThe redesigned Combitube enables fiberoptic bronchoscopy, fine-tuning of its position in the esophagus, and guided airway exchange in patients with normal airways. Further studies are warranted to demonstrate its value in patients with abnormal airways.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.