    Does anterior plating of the cervical spine predispose to adjacent segment changes?

    • Raj D Rao, Mei Wang, Linda M McGrady, Thomas J Perlewitz, and Kenny S David.
    • Department of Orthopaedic Surgery, Medical College of Wisconsin, Milwaukee, WI 53226, USA. rrao@mcw.edu
    • Spine. 2005 Dec 15; 30 (24): 2788-92; discussion 2793.

    Study DesignIn a human cadaveric model, the effects of plate supplementation on the mechanical behaviors of adjacent segments were investigated.ObjectivesThe objective was to determine the effects of anterior cervical fusion and plating on the adjacent segments.Summary Of Background DataIncreases in intradiscal pressure and intervertebral motion at adjacent segments have been reported in the lumbar spine following an instrumented fusion. It is unclear if the same phenomenon presents in the cervical spine.MethodsSeven human cadaveric cervical spines (C2-T1) were used, and fusion of the C5-C6 segment was chosen for the purpose of this study. Two miniature pressure transducers were implanted within each adjacent disc. Flexion, extension, lateral bending, and torsion loads up to 2.5 Nm were applied to the intact spine, and following each of the two procedures, anterior discectomy and grafted fusion, and anterior plating of the C5-C6 motion segment.ResultsAt the surgical level, a significant increase in segmental stiffness was observed after plating in all directions. Following the grafted fusion, there were no statistically significant changes at the superior adjacent segment, and there was a 13.7% increase in axial rotation in the inferior adjacent segment. Once anterior plating was applied, slight increase (<12%) over the intact spines was noted in lateral bending in both adjacent segments. However, there was no significant difference between the grafted fusion and anterior plated fusion at either adjacent segment. At both adjacent disc levels, the differences in intradiscal pressures between grafted fusion and plated fusion were less than 30% in all directions, and none of these differences was statistically significant.ConclusionsIntradiscal pressures and intervertebral motion at the adjacent levels are not significantly affected by the instrumented anterior fusion. The clinically observed degenerative change at adjacent segments in the cervical spine is more likely to be attributed to natural progression of the spondylotic process as opposed to biomechanical effect of the instrumentation or fusion.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.