• Journal of anesthesia · Aug 2017

    Comparative Study

    Comparison of stroke volume measurement between non-invasive bioreactance and esophageal Doppler in patients undergoing major abdominal-pelvic surgery.

    • Gennaro De Pascale, Mervyn Singer, and David Brealey.
    • Division of Medicine, Bloomsbury Institute of Intensive Care Medicine, University College London, Gower St, London, WC1E 6BT, UK. gennaro.depascalemd@gmail.com.
    • J Anesth. 2017 Aug 1; 31 (4): 545-551.

    PurposeBioreactance is a non-invasive technology for measuring stroke volume (SV) in the operating room and critical care setting. We evaluated how the NICOM®bioreactance device performed against the CardioQ®esophageal Doppler monitor in patients undergoing major abdominal-pelvic surgery, focusing on the effect of different hemodynamic interventions.MethodsSVNICOMand SVODMwere simultaneously measured intraoperatively, including before and after interventions including fluid challenge, vasopressor boluses, peritoneal gas insufflation/removal, and Trendelenburg/reverse Trendelenburg patient positioning.ResultsA total of 768 values were collected from 21 patients. Pre- and post-intervention measures were recorded on 155 occasions. Bland-Altman analysis revealed a bias of 8.6 ml and poor precision with wide limits of agreement (54 and -37 ml) and a percentage error of 50.6%. No improvement in precision was detected after taking into account repeated measurements for each patient (bias: 8 ml; limits of agreement: 74 and -59 ml). Concordance between changes in SVNICOMand SVODMbefore and after interventions was also poor: 78.7% (all measures), 82.4% (after vasopressor administration), and 74.3% (after fluid challenge). Using Doppler SV as the reference technique, the area under the receiver operating characteristic curve assessing the ability of the NICOM device to predict fluid responsiveness was 0.81 (0.7-0.9).ConclusionsIn patients undergoing major abdomino-pelvic surgery, SV values obtained by NICOM showed neither clinically or statistically acceptable agreement with those obtained by esophageal Doppler. Although, in the setting of this study, bioreactance technology cannot reliably replace esophageal Doppler monitoring, its accuracy for predicting fluid responsiveness was higher, up to approximately 80%.Trial RegistrationObservational study.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.