• Spine · May 2017

    C-arm Positioning Is a Significant Source of Radiation in Spine Surgery.

    • Elizabeth W Reiser, Rupen Desai, Sarah A Byrd, Harrison Farber, Deborah Chi, Cary S Idler, and Robert E Isaacs.
    • Department of Neurosurgery, Duke University Medical Center, Durham, NC.
    • Spine. 2017 May 1; 42 (9): 707-710.

    Study DesignProspective chart review.ObjectiveIt is well-known that radiation exposure during minimally invasive spine procedures can be substantial. Less interest has focused on setup radiation exposure before incision, including preoperative images used for surgical approach. The present study seeks to better quantify the significance of setup radiation in the total radiation exposure of minimally invasive spine surgery.Summary Of Background DataRadiographic localization is necessary in minimally invasive spine procedures to visualize anatomy, but increased radiation exposure is associated with health risks. Preoperative imaging for anatomical localization has not been previously analyzed as an appreciable source of radiation.MethodsFrom an institutional review board-approved database of more than 1100 procedures, the minimally invasive spine cases with recorded set-up radiation were extracted. The total radiation, set-up radiation, and procedure type data were evaluated. Statistics were generated using a chi-squared analysis.ResultsSet-up and total radiation data were collected for 270 spine surgeries performed by four surgeons at two locations. There were 30 thoracic and 240 thoracolumbar/lumbar cases; 78 anterior and 192 posterior cases. Average total radiation (set-up and intraoperative) was 8.04 rad, and average setup radiation was 1.90 rad (28%, std 2.97 rad) across all cases. On average for the thoracolumbar/lumbar cases, set-up radiation accounted for almost 25% of total radiation with 1.76 rad from setup out of 8.16 rad total. Thoracic-only cases often necessitated even more images for localization, generating an average set-up/total percentage of 52%. Across all procedures, set-up radiation significantly increased the total radiation exposure because it accounted for more than 25% of the total procedure.ConclusionRadiation exposure during preoperative localization can be substantial. Operating room personnel should recognize the high percentage of radiation that occurs during set-up, and merit should be given to techniques and technologies that can limit unnecessary radiation exposure during this portion of the procedure.Level Of Evidence2.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…