Analyzing 3-tesla magnetic resonance imaging units for implementation in radiosurgery.
- Andreas Mack, Robert Wolff, Stefan Scheib, Marcus Rieker, Dirk Weltz, G Mack, Hans-Jürg Kreiner, Ulrich Pilatus, Friedhelm E Zanella, Heinz D Böttcher, and Volker Seifert.
- Gamma Knife Centre, Frankfurt, Germany. a.mack@gkfrankfurt.de
- J. Neurosurg. 2005 Jan 1; 102 Suppl: 158-64.
ObjectThe limiting factor affecting accuracy during gamma knife surgery is image quality. The new generation of magnetic resonance (MR) imaging units with field strength up to 3 teslas promise superior image quality for anatomical resolution and contrast. There are, however, questions about chemical shifts or susceptibility effects, which are the subject of this paper.MethodsThe 3-tesla MR imaging unit (Siemens Trio) was analyzed and compared with a 1-tesla unit (Siemens Magnetom Expert) and to a 1.5-tesla unit (Philips Gyroscan). Evaluation of the magnitude of error was performed within transverse slices in two orientations (axial/coronal) by using a cylindrical phantom with an embedded grid. Deviations were determined for 21 targets in a slab phantom with known geometrical positions within the stereotactic frame. Distortions caused by chemical shift and/or susceptibility effects were analyzed in a head phantom. Inhouse software was used for data analyses. The mean deviation was less than 0.3 mm in axial and less than 0.4 mm in coronal orientations. For the known targets the maximum deviation was 1.16 mm. By optimizing these parameters in the protocol these inaccuracies could be reduced to less than 1.1 mm. Due to inhomogeneities a shift in the z direction of up to 1.5 mm was observed for a dataset, which was shown to be compressed by 1.2 mm.ConclusionsThe 3-tesla imaging unit showed superior anatomical contrast and resolution in comparison with the established 1-tesla and 1.5-tesla units; however, due to the high field strength the field within the head coil is very sensitive to inhomogeneities and therefore 3-tesla imaging data will have be handled with care.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.