-
- Oran D Kennedy, Orlaith Brennan, Nicholas J Mahony, Susan M Rackard, Fergal J O'Brien, David Taylor, and Clive T Lee.
- Department of Anatomy, Royal College of Surgeons in Ireland, Dublin, Ireland. okennedy@rcsi.ie
- Spine. 2008 Nov 1; 33 (23): 2518-23.
Study DesignInvestigations of the effects of high bone turnover on the L3 vertebra were carried out, using an ovariectomized (OVX) ovine model of early stage osteoporosis.ObjectiveTo assess the contribution of bone turnover to the biomechanics of L3.Summary Of Background DataClinically, dual energy x-ray absorptiometry (DEXA) is used to measure bone mineral density (BMD). However, this can only predict 60% to 70% of bone strength; the remainder is due to bone quality. There is currently little information available on how strength is affected by changes in bone quality parameters, particularly bone turnover. Turnover can be assessed clinically using biochemical markers; however, this provides systemic values, whereas localized values are required to predict site-specific fracture risk.MethodsThirty-eight sheep were assigned to 2 groups (control, n = 19; OVX, n = 19). Both groups were intravenously administered a fluorochrome dye on the day of surgery and 3, 6, 9, and 12 months thereafter, to label sites of bone turnover. After 12 months, animals were killed and the spinal columns harvested. L3 vertebrae were scanned using DEXA. Bone turnover was quantified using epifluorescence microscopy, and microarchitecture was assessed by microCT scanning. Compressive testing was used to characterize the mechanical properties of the vertebrae.ResultsBMD and microarchitecture were unchanged in OVX compared with controls. However, bone turnover, as measured by fluorochrome labeled sites, was significantly increased in the OVX group in cortical and trabecular compartments. As a consequence, the biomechanical properties were significantly reduced in that group.ConclusionThese findings show that OVX resulted in changes in bone turnover, which reduced biomechanical properties in a model of early stage osteoporosis. These differences were present despite microarchitecture or BMD remaining unchanged. In the future, the ability to assess site-specific bone turnover would greatly enhance the accuracy with which fracture risk could be predicted.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.