    Utility of Thoracolumbar Low-Dose CT with Model-Based Iterative Reconstruction for Measuring Pedicle Diameter Using a Radiation Dose Less Than a One-Time Lumbar X-Ray.

    • Kazutaka Masamoto, Shunsuke Fujibayashi, Bungo Otsuki, Kentaro Hara, Yasuhiro Fukushima, Koji Koizumi, Takayoshi Shimizu, Yu Shimizu, Kazuaki Morizane, Koichi Murata, and Shuichi Matsuda.
    • Department of Orthopaedic Surgery, Graduate School of Medicine, Kyoto University, Kyoto, Japan.
    • Spine. 2020 Jan 1; 45 (1): 38-47.

    Study DesignRetrospective.ObjectiveTo evaluate the image quality of low-radiation-dose computed tomography (LD-CT) of the thoracolumbar spine, using model-based iterative reconstruction (MBIR) for measuring pedicle diameter.Summary Of Background DataMBIR can drastically reduce radiation dose but its utility in spine surgery planning is unknown.MethodsWe identified patients (mean age, 70.5 ± 13.3 yrs) who incidentally underwent both standard-radiation-dose CT (SD-CT) with hybrid iterative reconstruction and LD-CT with MBIR of the thoracolumbar spine within 2 years. We compared radiation dose, subjective image sharpness, signal-to-noise ratio, and contrast-to-noise ratio for the two tests. Additionally, inner pedicle diameters were measured on SD-CT (DSD) and LD-CT (DLD), and statistically compared.ResultsWe included 24 CT and 84 pedicles for each CT group. The radiation dose of LD-CT estimated by volume CT dose index was 1.21 ± 0.42 mGy, one-sixth the dose of SD-CT. The effective dose of LD-CT was 0.58 ± 0.31 mSv, equivalent to or less than that of a one-time lumbar X-ray in a previous report. LD-CT was significantly inferior in subjective image sharpness for the contour of vertebrae and trabecular structure, but superior for signal-to-noise ratio and contrast-to-noise ratio. The intra-rater reliability (intra-RR) and inter-RR for DLD were 0.985 and 0.892, respectively, comparable to those of DSD. DLD was consistently 0.30 mm smaller than DSD when compared within the same pedicle, regardless of pedicle diameter.ConclusionLD-CT with MBIR produced a radiation dose equivalent to a one-time lumbar X-ray and provided excellent images for measuring pedicle diameter. LD-CT can be a substitute for SD-CT when planning spine surgery if the relationship between DSD and DLD is sufficiently understood.Level Of Evidence3.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…