• Spine · Apr 2020

    Effects of Surface Topography and Chemistry on Polyether-Ether-Ketone (PEEK) and Titanium Osseointegration.

    • F Brennan Torstrick, Angela S P Lin, David L Safranski, Daniel Potter, Todd Sulchek, Christopher S D Lee, Ken Gall, and Robert E Guldberg.
    • George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA.
    • Spine. 2020 Apr 15; 45 (8): E417-E424.

    Study DesignAn in vivo study examining the functional osseointegration of smooth, rough, and porous surface topographies presenting polyether-ether-ketone (PEEK) or titanium surface chemistry.ObjectiveTo investigate the effects of surface topography and surface chemistry on implant osseointegration.Summary Of Background DataInterbody fusion devices have been used for decades to facilitate fusion across the disc space, yet debate continues over their optimal surface topography and chemistry. Though both factors influence osseointegration, the relative effects of each are not fully understood.MethodsSmooth, rough, and porous implants presenting either a PEEK or titanium surface chemistry were implanted into the proximal tibial metaphyses of 36 skeletally mature male Sprague Dawley rats. At 8 weeks, animals were euthanized and bone-implant interfaces were subjected to micro-computed tomography analysis (n = 12), histology (n = 4), and biomechanical pullout testing (n = 8) to assess functional osseointegration and implant fixation.ResultsMicro-computed tomography analysis demonstrated that bone ingrowth was 38.9 ± 2.8% for porous PEEK and 30.7 ± 3.3% for porous titanium (P = 0.07). No differences in fixation strength were detected between porous PEEK and porous titanium despite titanium surfaces exhibiting an overall increase in bone-implant contact compared with PEEK (P < 0.01). Porous surfaces exhibited increased fixation strength compared with smooth and rough surfaces regardless of surface chemistry (P < 0.05). Across all groups both surface topography and chemistry had a significant overall effect on fixation strength (P < 0.05), but topography accounted for 65.3% of the total variance (ω = 0.65), whereas surface chemistry accounted for 5.9% (ω = 0.06).ConclusionsThe effect of surface topography (specifically porosity) dominated the effect of surface chemistry in this study and could lead to further improvements in orthopedic device design. The poor osseointegration of existing smooth PEEK implants may be linked more to their smooth surface topography rather than their material composition.Level Of EvidenceN/A.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…