• Arch Orthop Trauma Surg · Aug 2011

    Comparative Study

    Structural properties of a new fixation strategy in double bundle ACL reconstruction: the MiniShim.

    • S Lenschow, B Schliemann, K Dressler, B Zampogna, S Vasta, M Raschke, and T Zantop.
    • Department of Trauma-, Hand- and Reconstructive Surgery, Wilhelms University Muenster, Muenster, Germany, simon.lenschow@ukmuenster.de.
    • Arch Orthop Trauma Surg. 2011 Aug 1; 131 (8): 1159-65.

    IntroductionDouble-bundle reconstruction of the ACL has become the focus of scientific and clinical interest in the last years. However, there is still a discussion about the most appropriate technique for graft fixation. Both, extracortical fixation systems like the Endobutton and aperture fixation by interference screws have advantages as well as disadvantages. Aim of this study was to analyze the biomechanical properties of a new small wedge shaped implant (MiniShim, Karl Storz, Germany) for the fixation of a soft tissue graft in double bundle ACL reconstruction and to compare it to an aperture fixation by interference screw and an extracortical fixation.MethodsPorcine knees and flexor tendons were used for this study. 5 and 6 mm tunnels were drilled. The following fixation strategies were tested: 4 and 5 mm MiniShim (Karl Storz Germany), 6 mm interference screw (MegaFix, Karl Storz, Germany), hybridfixation by FlippTack (FlippTack, Karl Storz, Germany) and MiniShim and hybridfixation by FlippTack and 6 mm interference screw. All fixation strategies were tested with a 5 and 6 mm tendon graft. Maximum load, yield load and stiffness were recorded using a material testing machine. Load was applied in line with the bone tunnel. Grafts were cyclically preconditioned between 0 and 20 N for 10 cycles before the graft-bone-complex was loaded to failure. Statistical evaluation was performed using SPSS Version 11.0.ResultsLoad to failure for the 5 mm graft was 81.1 and 118.0 N for the 4 and 5 mm MiniShims. Fixation by interference screw reached 237.4 N. The extracortical fixation resulted in a load to failure of 471.7 N. Load to failure for the 6 mm tendon grafts was 52.0 and 92.8 N for the 4 and 5 mm MiniShims. Fixation by interference screw resulted in a load to failure of 214.0 N. Extracortical fixation failed at 451.7 N. The difference between MiniShim and interference screw was statistically significant. Load to failure was significantly higher for extracortical fixation compared to fixation by MiniShim or interference screw. Hybrid fixation showed higher fixation strength compared to fixation by interference screw or MiniShim alone. This difference was statistically significant. Stiffness was significantly higher for fixation by interference screw compared to extracortical fixation and fixation by MiniShim. Four different modes of failure could be seen. All 4 mm MiniShims failed by slippage of the tendon past the MiniShim. In the 5 mm group the fixation failed by pullout of the MiniShim or the tendon past the MiniShim. Hybrid fixation failed by rupture of the linkage material. When the graft was fixed by an interference screw failure occurred by rupture of the tendon at the fixation side.ConclusionHybrid fixation using the MiniShim provides biomechanical properties strong enough to withstand the forces occurring during rehabilitation and comparable to the fixation strength provided by interference screw. While fixation by MiniShim alone does not provide sufficient fixation strength in double bundle ACL reconstruction, hybridfixation using a cortical fixation by FlippTack is an alternative to aperture fixation by interference screw concerning primary stability.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.